Heating coil
Requires no maintenance. Check at least twice a year for any possible mechanical damage and clean the
finned pack, controlling that the air flow is not obstructed by dirt or other material
Transmission belt of the rotor
Check at regular intervals the correct belt tension. It is kept under tension by the tensioning device and
requires no adjustments during normal operation.
Seals
Check seals regularly for any damage or dust.
Overall summary service intervals
Filters
Efficiency of the
rotor
Engines
Belt of the rotor
Coil
Seal
When necessary
Every 6 months
Every 12 months
Inspection
During installation or when you need to work on the unit, you must strictly follow the rules reported on
this manual, follow the instructions on the unit and take any necessary precautions. Failure to follow the
instructions set can cause dangerous situations. After receiving the unit, verify the completeness of the
dryer: the unit left the factory in perfect condition; any damage must be immediately reported to the
carrier and recorded on the Delivery Note before signing it. The Company must be informed the extent
of the damage within 8 days. The Customer must prepare a written statement of any severe damage.
Before accepting delivery, check:
that the machine has not been damaged during transport;
that the machine is the same as specified in the transport document
In case of damage or abnormalities:
note immediately damage on the delivery page;
inform the supplier of the extent of the damage, within 8 days of receipt. Reports after this
deadline are not valid ;
in the event of substantial damage prepare a written statement.