27
T
roubleshooting
The following conditions are not malfunction
Symptom Reason
After the end of drying and sounding of buzzer,
the dryer is still operating.
SOFTEN & COOL mode is operating.
It takes some time for the OPERATION lamp to
turn on red.
The dryer has not been used for a long time.
Please keep on operating for a while.
In cold season, white smokes emerge from
exhaust duct outlet.
This is mist resulted from cooling of water
vapour in ue gas.
There is pop sound during ignition. This is normal sound of ignition.
There is noise of metal rubbing. The zippers or fasteners on clothes rub
against or bump against the drum.
There is hissing noise after drying nishes. The sound is due to contraction of metal
components when cooling down.
The sound of ignition appears after fan operation. The ignition is made after conrming normal
operation of fan.
The remaining time in the digital display is not
changed for a while or increase in value.
The system adjusts time estimation
periodically according to detected drying
temperature and clothes humidity.
The OPERATION lamp lights up red or green
alternately.
The burner is turned on and off alternately in
order to regulate the drying temperature.
Warning
Never repair the dryer by yourself
If not handle properly, it may cause re and electric
shock.