The following conditions are not malfunction
Symptom Reason
After the end of drying and sounding of buzzer,
the dryer is still operating.
• SOFTEN & COOL mode is operating.
It takes some time for the OPERATION lamp to
turn on red.
• The dryer has not been used for a long time.
Please keep on operating for a while.
In cold season, white smokes emerge from
exhaust duct outlet.
• This is mist resulted from cooling of water
vapour in ue gas.
There is pop sound during ignition. • This is normal sound of ignition.
There is noise of metal rubbing. • The zippers or fasteners on clothes rub
against or bump against the drum.
There is hissing noise after drying nishes. • The sound is due to contraction of metal
components when cooling down.
The sound of ignition appears after fan operation. • The ignition is made after conrming normal
operation of fan.
The remaining time in the digital display is not
changed for a while or increase in value.
• The system adjusts time estimation
periodically according to detected drying
temperature and clothes humidity.
The OPERATION lamp lights up red or green
alternately.
• The burner is turned on and off alternately in
order to regulate the drying temperature.
Warning
• Never repair the dryer by yourself
• If not handle properly, it may cause re and electric
shock.