payShield 10K Installation and User Guide
©Thales Group
Page 259
All Rights Reserved
Configure Alarms (CL)
Variant
Key Block
Online
Offline
Secure
Authorization: Not required
Command:
CL
Function:
To enable or disable the motion alarm. The temperature alarm is permanently
enabled. The HSM alarm circuitry typically needs to be turned off if the HSM
is to be moved. The alarm should be turned on while the HSM is in service or
being stored. The alarm setting can optionally be saved to a smartcard.
Authorization:
The HSM must be in the secure state to run this command.
Inputs:
Motion alarm status: Low, Medium, High or Off.
Save settings to smartcard: Yes or No.
Outputs:
None.
Errors:
Card not formatted to save/retrieve HSM settings.
Attempt with another card? [Y/N]
Example 1:
In this example, the setting is being made to a less secure setting.
Secure> CL <Return>
Please make a selection. The current setting is in
parentheses.
Motion alarm [Low/Med/High/OFF] (MED): F <Return>
LMKs must be erased before proceeding.
Erase LMKs?? [Y/N]: Y<Return>
Save ALARM settings to smart card? [Y/N]: N <Return>
Secure>
Example 2:
In this example, the setting is being made to a more secure setting.
Secure> CL <Return>
Please make a selection. The current setting is in
parentheses.
Motion alarm [Low/Med/High/OFF] (OFF): H <Return>
Save ALARM settings to smart card? [Y/N]: N <Return>
Secure>