TROUBLESHOOTING :
If water is not clear, check the following:
• Check that the UVC Filter is operating. If the UVC lamp has overheated due to lack
of water ow it will automatically turn o. Allow lamp to cool then reconnect.
• Replace UVC bulb if it has not been replaced in the past year, even if it is operational.
• Check that the quartz sleeve is clean and not damaged.
• Verify that the proper amount of water is owing through the lter. See
recommendation for proper water ow on the Technical Specs chart.
• Verify that lter media is not plugged with debris or needs cleaning.
Loss of water ow, check the following:
• Verify pump is not plugged with debris.
• Verify lter media is not plugged with debris.
• Verify lter is not leaking causing a loss of pressure.
Filter is leaking, check the following:
• Verify that the proper amount of water is owing through the lter. See
recommendation for proper water ow on the Technical Specs chart.
• Verify O-rings are seated correctly.
• Verify lter canister has not been damaged.
MAINTAINING YOUR ALLCLEAR
™
G2 FILTER:
thepondguy.com | 866-POND-HELP (766-3435)