Cautions
Always wear a heat resistant glove to touch the stainless steel probe sensor or wire
during or just after cooking. Do not touch with bare hands.
Keep the stainless steel probe sensor and wire away from children.
Not Intended for Use by Persons ages 12 and Under.
Clean the stainless steel probe and dry thoroughly after each and every use.
Do not immerse the probe or wire in water. Use a damp, soapy cloth to Clean.
Do not use the receiver or transmitter in the rain. They are not waterproof.
Do not expose the plug of the stainless steel probe or the plug in hole of the
to water or any liquid. This will result in a bad connection and faulty readings.
transmitter
Do not expose the receiver or transmitter to direct heat or surface.
Do not use stainless steel probe in microwave oven.
Count up
1. Press MODE to select timer mode. The upper display will show a small TIMER and 0:00.
2. Press START/STOP button to start count up. The “ ” will blink for every second.
3. To stop the count up process, press START/STOP button. The “ ” becomes solid.
4. Press CLEAR button to clear the setting back to 0:00.
HELPFUL HINTS
Do not immerse the probe in water while cleaning.
Do not allow the probe or probe wire to come into contact with flames. If cooking with
grill cover closed, only use medium or low heat.
If the probe becomes defective within 90 days warranty period please return
probe to address below along with return address and we will send you a new probe no
charge.
defective
If the temperature displayed seems to read too high or the temperature seems to
increase too quickly check to make sure the probe tip is not poking through the food to
outside. Reposition the probe tip in the center of the thickest part of food. Avoid touching
bone or heavy fat areas.
-7-
HELPFUL HINTS
If the receiver and/or the transmitter display LLL or HHH instead of the probe temperature,
wait for probe to reach room temperature. If LLL or HHH is still displayed, it is likely the
internal probe wire has shorted out either through moisture or heat damage.
Using the Timer
Count down
1. Press MODE to select timer mode. The upper display will show a small TIMER and 0:00.
2. Press HR and MIN button to set the timer. Press START/STOP button to start
” will blink for every second.
countdown.
3. To stop the countdown process, press START/STOP button. The “ ” becomes solid.
4. Press HR & MIN buttons together to clear the setting back to 0:00.
Note: The minimum setting for the timer is 1 minute. When the timer counts down below
1 hour 1:00 the display will change to 59'59" to indicate, 59 minutes 59 seconds. The
seconds will be shown counting down then. When the countdown reaches 0'00” the timer
starts counting up and it will beep for 60 seconds. The timer and “ ” will blink. Press
the START/S TOP button to stop beeping. When the c ount up r eaches 23:5 9:59 (59
seconds are not displayed) the display will turn to 0:00, the unit beeps and “ ” will blink
for 60 seconds.
Cleaning
Always wear a heat resistant glove to touch the stainless steel probe sensor or wire
during or just after cooking. Do not touch with bare hands.
Keep the stainless steel probe sensor and wire away from children.
Wash the metal probe tip with hot soapy water and dry thoroughly. Do not immerse the
probe in water while cleaning.
Wipe the transmitter and receiver with damp cloth. Do not immerse either in water.
FCC Statement
1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may
cause undesired operation.
2. Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
LIMITED 90 DAYS WARRANTY
ThermoPro warrants this product to be free of defects in parts, materials and workmanship
for a period of 90 days, from date of purchase.
Should any repairs or servicing under this warranty be required, contact Customer Service
by phone or email for instructions on how to pack and ship the product to ThermoPro.
This warranty gives you specific legal rights and you may also have other rights which
vary from state to state.
CUSTOMER SERVICE
Telephone: 1-877-515-7797 (US&CA only)
Email: service@buythermopro.com
Hours: Weekdays 9:00 AM- 5:00 PM EST
-6-