2
PRODUCT SPECIFICATIONS
Model WDFT060-VF WDFT100-VF WDFT320-VF
BTU(available)
6000 10000 32000
Gas type Using natural gas Using natural gas Using natural gas
Press regulator setting 4 in w.c. 4 in w.c. 4 in w.c.
Inlet gas pressure(inches of water) for purpose of input adjustment
Maximum 7 in w.c. 7 in w.c. 7 in w.c.
Minimum 5 in w.c. 5 in w.c. 5 in w.c.
Gas type Using propane gas Using propane gas Using propane gas
Press regulator setting 11 in w.c. 11 in w.c. 11 in w.c.
inlet gas pressure(inches of water) for purpose of input adjustment
Maximum 14 in w.c. 14 in w.c. 14 in w.c.
Minimum 11 in w.c. 11 in w.c. 11 in w.c.
Ignition Electric Piezo Electric Piezo Electric Piezo
Dimension inches
(H×W×D)
15.7×7.5×25.6 18.1×7.5×28.7 30.7×9.1×29.5
Important Note:
1) An unvented room heater having an input rating of more than 10,000 Btu/hr
(2,931 W) shall not be installed in a bedroom or bathroom; or
2) An unvented room heater having an input rating of more than 6000 Btu/hr
(1,758 W) shall not be installed in a bathroom.