Vent-Free Gas Wall Heater
MODEL: WDFT060/100/320-VF (DUAL FUEL)
WNT060/100/320-VF (NATURAL GAS)
WLT060/100/320-VF (PROPANE GAS)
CAUTION - FOR YOUR SAFETY
Reecon North America
2
nd
Floor
1090 Freeport Road
Pittsburgh, PA 15238
Conforms to ANSI Z21.11-2b-2013. Gas-Fired Room Heater Volume II, Unvented Room Heater
This is an unvented gas-fired heater. It uses air (oxygen) from the room in
which it is installed. Provisions for adequate combustion and ventilation
air must be provided. Refer to Air For Combustion and Ventilation
section on pa
g
e 8 of this manual. Warranty is void if not professionally installed.
INSTALLER: Leave this manual with the appliance
CONSUMER: Retain this manual for future reference
This appliance may be installed in an aftermarket, permanently located,
manufactured (mobile) home, where not prohibited by local codes.
This appliance is only for use with propane or natural gas.
This appliance is equipped with a simple means to switch between
propane and natural gas in dual fuel models only. Field conversion by
any other means including the use of a kit is not permitted.
WARNING: This appliance is equipped for
(Natural and/or Propane) gas. Field
conversion is not permitted other than
between natural or propane gases in dual
fuel models only.

Other manuals for Thermablaster WDFT060

Questions and Answers

  • C
    Carly CaldwellSep 18, 2025
    Why is there moisture on windows from Thermablaster Gas Heater?
    • W
      wongjeremySep 18, 2025
      If you notice unexpected moisture or condensation on the windows when using your Thermablaster Gas Heater, use a dehumidifier if the ambient moisture is too high.
  • H
    harryhubbardAug 25, 2025
    What to do if Thermablaster Gas Heater shuts off in use (ODS operates)?
    • D
      Daniel RubioAug 25, 2025
      If your Thermablaster Gas Heater shuts off while in use and the ODS is operating, it could be due to a lack of fresh air. Try opening a window or door for ventilation. Another potential cause is low line pressure, in which case you should contact your local gas supplier. A partially clogged ODS/pilot could also be the reason; try cleaning it.
  • R
    Robert HarrisAug 25, 2025
    Why Thermablaster WDFT060 Gas Heater burner(s) does not light after ODS/pilot is lit?
    • R
      Robert RodgersAug 26, 2025
      If the burner(s) on your Thermablaster Gas Heater doesn't light after the ODS/pilot is lit, the burner orifice may be clogged. Try cleaning the burner orifice, or consider replacing it. In some cases, the burner orifice diameter might be too small, or the inlet gas pressure could be too low.
  • T
    Tracy OrtizAug 27, 2025
    What to do if ODS/pilot lights but flame goes out when control knob is released on Thermablaster WDFT060 Gas Heater?
    • K
      Kristi SawyerAug 27, 2025
      If the ODS/pilot lights, but the flame goes out when you release the control knob on your Thermablaster Gas Heater, make sure the control knob is fully pressed in and held for at least 30 seconds after the ODS/pilot lights. Ensure the equipment shutoff valve is fully open. Also, check the thermocouple connection at the control valve and hand tighten it until it's snug, then tighten it an additional 1/4 turn. If the issue persists, the thermocouple might be damaged and require replacement.
  • A
    Anthony OlsonSep 19, 2025
    Why is there white powder residue from Thermablaster Gas Heater?
    • B
      Brad MartinSep 22, 2025
      If you notice white powder residue forming within the burner box or on adjacent walls or furniture when using your Thermablaster Gas Heater, turn the heater off when using furniture polish, wax, carpet cleaner, or similar products.
  • M
    mistymelendezSep 23, 2025
    Why is there smoke or odor from Thermablaster Gas Heater during initial operation?
    • M
      Mary DunnSep 23, 2025
      If you notice slight smoke or odor during the initial operation of your Thermablaster Gas Heater, it is likely due to residues from manufacturing processes. This problem should stop after a few hours of operation.
  • C
    Connor DiazSep 9, 2025
    How to fix Thermablaster Gas Heater when there is no spark at ODS/pilot?
    • F
      frankdawnSep 10, 2025
      If there's no spark at the ODS/pilot when the igniter knob is pressed on your Thermablaster Gas Heater, try these steps: * Reposition the igniter electrode. * Check all cables between the switch, battery pack, igniter, and igniter electrode. Secure or replace any that are loose, pinched, wet, or broken. * If the igniter is bad, replace it. * Install or replace the battery if there is none or if it's used up.
  • T
    Tyler CollinsSep 12, 2025
    How to stop gas odor during combustion in Thermablaster Gas Heater?
    • M
      Megan BensonSep 12, 2025
      If you notice a gas odor during combustion in your Thermablaster Gas Heater: * Locate and correct any gas leaks. * Remove any foreign materials that may be present in the heater.
  • T
    Taylor HillSep 3, 2025
    Why is there gas odor during combustion in Thermablaster WDFT060 Gas Heater?
    • N
      nicolebarberSep 3, 2025
      Gas odor during combustion in your Thermablaster Gas Heater can be caused by foreign matter between the control valve and burner. Take apart the gas tubing and remove any foreign matter. It can also be caused by gas leak.
  • M
    Matthew WebbSep 1, 2025
    What causes delayed ignition of burner(s) in Thermablaster WDFT060?
    • I
      Isaiah SinghSep 1, 2025
      Delayed ignition of the burner(s) in your Thermablaster Gas Heater can be caused by low manifold pressure. The burner orifice may also be clogged.