EasyManua.ls Logo

Thermablaster WDFT060 - User Manual

Thermablaster WDFT060
34 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
Vent-Free Gas Wall Heater
MODEL: WDFT060/100/320-VF (DUAL FUEL)
WNT060/100/320-VF (NATURAL GAS)
WLT060/100/320-VF (PROPANE GAS)
CAUTION - FOR YOUR SAFETY
Reecon North America
2
nd
Floor
1090 Freeport Road
Pittsburgh, PA 15238
Conforms to ANSI Z21.11-2b-2013. Gas-Fired Room Heater Volume II, Unvented Room Heater
This is an unvented gas-fired heater. It uses air (oxygen) from the room in
which it is installed. Provisions for adequate combustion and ventilation
air must be provided. Refer to Air For Combustion and Ventilation
section on pa
g
e 8 of this manual. Warranty is void if not professionally installed.
INSTALLER: Leave this manual with the appliance
CONSUMER: Retain this manual for future reference
This appliance may be installed in an aftermarket, permanently located,
manufactured (mobile) home, where not prohibited by local codes.
This appliance is only for use with propane or natural gas.
This appliance is equipped with a simple means to switch between
propane and natural gas in dual fuel models only. Field conversion by
any other means including the use of a kit is not permitted.
WARNING: This appliance is equipped for
(Natural and/or Propane) gas. Field
conversion is not permitted other than
between natural or propane gases in dual
fuel models only.

Other manuals for Thermablaster WDFT060

Questions and Answers

  • M
    Matthew WebbSep 1, 2025
    What causes delayed ignition of burner(s) in Thermablaster WDFT060?
    • I
      Isaiah SinghSep 1, 2025
      Delayed ignition of the burner(s) in your Thermablaster Gas Heater can be caused by low manifold pressure. The burner orifice may also be clogged.
  • J
    Jaclyn GoodAug 31, 2025
    Why is there yellow flame during burner combustion in Thermablaster WDFT060 Gas Heater?
    • Y
      youngrobertAug 31, 2025
      If there is a yellow flame during burner combustion in your Thermablaster Gas Heater, it could be due to not enough air. Check the burner for dirt and debris, and clean it if necessary. A defective gas regulator or low inlet gas pressure can also cause this issue.
  • M
    Mrs. Anna Baker MDAug 30, 2025
    Why is there a spark at ODS/pilot but no ignition on Thermablaster Gas Heater?
    • C
      clarkevanAug 30, 2025
      If there is a spark at the ODS/pilot but no ignition on your Thermablaster Gas Heater, first ensure the gas supply is turned on and the equipment shutoff valve is open. Make sure the control knob is fully pressed in while pressing the igniter button, and that it's in the PILOT position. If there is air in the gas lines from installation, continue holding down the control knob and repeat the igniting operation until the air is removed. Also, the ODS/pilot may be clogged so clean it. The gas regulator setting might not be correct, so replace the gas regulator. Finally, check for a depleted gas supply (propane) and contact your local propane/LP gas company if needed.
  • J
    joseph14Aug 29, 2025
    What to do if Thermablaster WDFT060 produces a whistling noise when burner is lit?
    • T
      Tanya CastanedaAug 29, 2025
      If your Thermablaster Gas Heater produces a whistling noise when the burner is lit, try turning the control knob to the LO position and let it warm up for a minute, especially if the burner is cold. The noise might also be due to air in the gas line. Operate the burner until the air is removed from the line. Blocked air passageways on the heater can also cause this, so observe minimum installation clearances. A dirty or partially clogged burner orifice can also be the cause, so clean the burner.
  • J
    Jamie TerrellAug 28, 2025
    What to do if Thermablaster WDFT060 Gas Heater burner backfiring during combustion?
    • P
      Patricia MunozAug 28, 2025
      If your Thermablaster Gas Heater burner is backfiring during combustion, the burner orifice might be clogged or damaged. Try cleaning the burner orifice or replacing it. The gas regulator could also be defective, so consider replacing it.
  • S
    sanchezsarahAug 27, 2025
    Why is there no spark at ODS/pilot when igniter button is pressed in Thermablaster WDFT060 Gas Heater?
    • W
      William StoutAug 27, 2025
      If there is no spark at the ODS/pilot when the igniter button is pressed on your Thermablaster Gas Heater, the igniter electrode might be positioned incorrectly or broken, so replace the igniter. Ensure the igniter electrode is connected to the igniter cable; reconnect it if necessary. The igniter cable may be pinched or wet; free it if pinched and keep it dry. If the igniter cable is broken, replace it. The piezo igniter could also be bad, so replace it if needed.
  • T
    Tracy OrtizAug 27, 2025
    What to do if ODS/pilot lights but flame goes out when control knob is released on Thermablaster WDFT060 Gas Heater?
    • K
      Kristi SawyerAug 27, 2025
      If the ODS/pilot lights, but the flame goes out when you release the control knob on your Thermablaster Gas Heater, make sure the control knob is fully pressed in and held for at least 30 seconds after the ODS/pilot lights. Ensure the equipment shutoff valve is fully open. Also, check the thermocouple connection at the control valve and hand tighten it until it's snug, then tighten it an additional 1/4 turn. If the issue persists, the thermocouple might be damaged and require replacement.
  • R
    Robert HarrisAug 25, 2025
    Why Thermablaster WDFT060 Gas Heater burner(s) does not light after ODS/pilot is lit?
    • R
      Robert RodgersAug 26, 2025
      If the burner(s) on your Thermablaster Gas Heater doesn't light after the ODS/pilot is lit, the burner orifice may be clogged. Try cleaning the burner orifice, or consider replacing it. In some cases, the burner orifice diameter might be too small, or the inlet gas pressure could be too low.
  • H
    harryhubbardAug 25, 2025
    What to do if Thermablaster Gas Heater shuts off in use (ODS operates)?
    • D
      Daniel RubioAug 25, 2025
      If your Thermablaster Gas Heater shuts off while in use and the ODS is operating, it could be due to a lack of fresh air. Try opening a window or door for ventilation. Another potential cause is low line pressure, in which case you should contact your local gas supplier. A partially clogged ODS/pilot could also be the reason; try cleaning it.