Page 1
C
A
N
A
D
IA
N
G
A
S
A
S
S
O
C
IA
TIO
N
APPROVED
®
DUAL-FUEL MODELS PRSE304, PRSE36 AND PRSE48
WARNING: Disconnect power before
installing. Before turning power ON,
be sure that all controls are in the
OFF position.
Gas Supply:
Natural Gas – 6 inch water column.
Propane Gas – 11 inch water column.
Electrical Power Supply:
PRSG304 and PRSG36 Models – 120 VAC, 60 Hz., 1Ph., 15 Amp circuit.
PRSE304 Model - 120/240 VAC, 60 Hz., 1Ph., 20 Amp circuit.
PRSE36 Models – 120/240 VAC, 60 Hz., 1Ph., 30 Amp circuit.
PRSE48 Models – 120/240 VAC, 60 Hz., 1Ph., 50 Amp circuit.
IMPORTANT: Save these instructions for the Local Electrical Inspector’s use.
INSTALLER: Please leave these Installation Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
IMPORTANT: LOCAL CODES VARY. INSTALLATION, ELECTRICAL CONNECTIONS,
GAS CONNECTIONS, AND GROUNDING MUST COMPLY WITH ALL APPLICABLE CODES.
INSTALLATION INSTRUCTIONS MANUAL
PROFESSIONAL RANGES
For Residential Use Only
ALL-GAS MODELS PRSG304 AND PRSG36,
Question and Answer IconNeed help?

Do you have a question about the Thermador PRSE304 and is the answer not in the manual?

Summary

Important Installation Information

General Warnings and Safety Precautions

Covers potential hazards like improper installation, gas leaks, and general appliance safety.

Step 1: Ventilation Requirements

Step 2: Cabinet Preparation

Range Placement and Cabinet Clearances

Outlines required clearances around the range and within cabinets for safe installation.

Gas and Electrical Supply Zones

Details the specific zones for gas and electrical connections for different range models.

Step 4: Installing the Anti-Tip Device

Range Tipping Hazard and Anti-Tip Device Necessity

Emphasizes the risk of tipping and the requirement to install the provided anti-tip device.

Electrical Shock Hazard During Installation

Warns about drilling into walls/floors and the risk of concealed electrical wires.

Anti-Tip Device Parts for All-Gas and Dual-Fuel Ranges

Identifies the specific parts kits required for all-gas and dual-fuel models.

Anti-Tip Bracket Mounting Guidelines

Provides general instructions on where and how to attach the anti-tip bracket to various wall materials.

Mounting Bracket Location for PRSG Ranges

Details the precise positioning of the mounting bracket for PRSG models against the wall or floor.

Range Engagement with Anti-Tip Device

Describes the final step of sliding the range and tilting to ensure the anti-tip device engages correctly.

Step 5: Gas Requirements and Hookup

Propane Conversion and High-Pressure Regulators

Explains propane conversion and the need for a high-pressure regulator on the gas tank.

Gas Hookup Procedure and Leak Testing

Outlines the steps for connecting the gas supply, including using pipe dope and leak testing.

Step 6: Electrical Requirements, Connection & Grounding

Recommended Grounding for PRSG Models

Explains the proper grounding method using a 3-prong receptacle for PRSG models.

Grounding Methods for PRSE Models

Outlines grounding procedures for PRSE models with 3 or 4 conductor power supplies.

Step 7: Backguard Installation

Step 8: Test and Adjustment

Pre-Test Checks and Burner Operation

Covers installing loose components, checking connections, and verifying burner ignition.

Summary

Important Installation Information

General Warnings and Safety Precautions

Covers potential hazards like improper installation, gas leaks, and general appliance safety.

Step 1: Ventilation Requirements

Step 2: Cabinet Preparation

Range Placement and Cabinet Clearances

Outlines required clearances around the range and within cabinets for safe installation.

Gas and Electrical Supply Zones

Details the specific zones for gas and electrical connections for different range models.

Step 4: Installing the Anti-Tip Device

Range Tipping Hazard and Anti-Tip Device Necessity

Emphasizes the risk of tipping and the requirement to install the provided anti-tip device.

Electrical Shock Hazard During Installation

Warns about drilling into walls/floors and the risk of concealed electrical wires.

Anti-Tip Device Parts for All-Gas and Dual-Fuel Ranges

Identifies the specific parts kits required for all-gas and dual-fuel models.

Anti-Tip Bracket Mounting Guidelines

Provides general instructions on where and how to attach the anti-tip bracket to various wall materials.

Mounting Bracket Location for PRSG Ranges

Details the precise positioning of the mounting bracket for PRSG models against the wall or floor.

Range Engagement with Anti-Tip Device

Describes the final step of sliding the range and tilting to ensure the anti-tip device engages correctly.

Step 5: Gas Requirements and Hookup

Propane Conversion and High-Pressure Regulators

Explains propane conversion and the need for a high-pressure regulator on the gas tank.

Gas Hookup Procedure and Leak Testing

Outlines the steps for connecting the gas supply, including using pipe dope and leak testing.

Step 6: Electrical Requirements, Connection & Grounding

Recommended Grounding for PRSG Models

Explains the proper grounding method using a 3-prong receptacle for PRSG models.

Grounding Methods for PRSE Models

Outlines grounding procedures for PRSE models with 3 or 4 conductor power supplies.

Step 7: Backguard Installation

Step 8: Test and Adjustment

Pre-Test Checks and Burner Operation

Covers installing loose components, checking connections, and verifying burner ignition.

Thermador PRSE304 Specifications

General IconGeneral
BrandThermador
ModelPRSE304
CategoryRanges
Fuel TypeElectric
Number of Burners4
Oven TypeConvection
Width30 inches
ColorStainless Steel
Number of Elements4
Self-CleaningYes
Control TypeKnobs