DUAL-FUEL MODELS PRSE304, PRSE36 AND PRSE48
WARNING: Disconnect power before
installing. Before turning power ON,
be sure that all controls are in the
OFF position.
Gas Supply:
Natural Gas – 6 inch water column.
Propane Gas – 11 inch water column.
Electrical Power Supply:
PRSG304 and PRSG36 Models – 120 VAC, 60 Hz., 1Ph., 15 Amp circuit.
PRSE304 Model - 120/240 VAC, 60 Hz., 1Ph., 20 Amp circuit.
PRSE36 Models – 120/240 VAC, 60 Hz., 1Ph., 30 Amp circuit.
PRSE48 Models – 120/240 VAC, 60 Hz., 1Ph., 50 Amp circuit.
IMPORTANT: Save these instructions for the Local Electrical Inspector’s use.
INSTALLER: Please leave these Installation Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
IMPORTANT: LOCAL CODES VARY. INSTALLATION, ELECTRICAL CONNECTIONS,
GAS CONNECTIONS, AND GROUNDING MUST COMPLY WITH ALL APPLICABLE CODES.
INSTALLATION INSTRUCTIONS MANUAL
PROFESSIONAL RANGES
For Residential Use Only
ALL-GAS MODELS PRSG304 AND PRSG36,
Question and Answer IconNeed help?

Do you have a question about the Thermador PRSG304 and is the answer not in the manual?

Summary

STEP 1: VENTILATION REQUIREMENTS

STEP 2: CABINET PREPARATION

Gas and Electrical Supply Zones

Defines specific areas for gas and electrical connections relative to the range.

STEP 4: INSTALLING ANTI-TIP DEVICE

STEP 5: GAS REQUIREMENTS AND HOOKUP

Natural Gas Requirements

Specifies inlet connection, supply pressure, and manifold pressure for natural gas.

Propane Gas Requirements

Specifies inlet connection, supply pressure, and manifold pressure for propane gas.

STEP 6: ELECTRICAL REQUIREMENTS, CONNECTION & GROUNDING

Recommended Grounding Method - Models PRSG304 and PRSG36

Details the proper grounding method for all-gas 30" and 36" ranges.

Grounding Method Models PRES304, PRSE36 and PRSE48

Details grounding methods for dual-fuel ranges.

Summary

STEP 1: VENTILATION REQUIREMENTS

STEP 2: CABINET PREPARATION

Gas and Electrical Supply Zones

Defines specific areas for gas and electrical connections relative to the range.

STEP 4: INSTALLING ANTI-TIP DEVICE

STEP 5: GAS REQUIREMENTS AND HOOKUP

Natural Gas Requirements

Specifies inlet connection, supply pressure, and manifold pressure for natural gas.

Propane Gas Requirements

Specifies inlet connection, supply pressure, and manifold pressure for propane gas.

STEP 6: ELECTRICAL REQUIREMENTS, CONNECTION & GROUNDING

Recommended Grounding Method - Models PRSG304 and PRSG36

Details the proper grounding method for all-gas 30" and 36" ranges.

Grounding Method Models PRES304, PRSE36 and PRSE48

Details grounding methods for dual-fuel ranges.

Thermador PRSG304 Specifications

General IconGeneral
BrandThermador
ModelPRSG304
CategoryRanges
Fuel TypeGas
Number of Burners4
Oven Capacity4.4 cu. ft.
Oven TypeConvection
Self-CleaningYes
Width30 inches
ColorStainless Steel
Burner Power18, 000 BTU

Related product manuals