EasyManua.ls Logo

Thermia Calibra Cool User Manual

Thermia Calibra Cool
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Installation Guide
Calibra Cool
BW & WW models
www.thermia.com
Question and Answer IconNeed help?

Do you have a question about the Thermia Calibra Cool and is the answer not in the manual?

Thermia Calibra Cool Specifications

General IconGeneral
BrandThermia
ModelCalibra Cool
CategoryHeat Pump
LanguageEnglish

Summary

About the document

Document Overview and Scope

Provides an overview of the manual's purpose and scope for installers.

Important Safety and Warning Information

Highlights critical safety warnings and symbols to prevent injury or damage.

Electrical Installation Safety Precautions

Details safety precautions for electrical installations, including isolation methods.

Safety Valve Requirements and Installation

Specifies requirements for safety valve pipes and their connection to the drain.

Heat Pump and Refrigerant Disposal Procedures

Outlines procedures and regulations for safely scrapping the heat pump.

Procedure for Emptying Water Tank Before Scrapping

Step-by-step guide on how to empty the water tank before unit disposal.

Recommended Water Quality for Heating Systems

Discusses the importance of water quality and measures to maintain system performance.

Calibra Cool Application and Model Variations

Describes the intended uses and variations of the Calibra Cool models.

BW Model Collector Length Guidelines

Provides guidance on determining the optimal collector length for BW models.

System Overview Diagram and Components

Illustrates the overall system with key components and flow paths.

Heat pump data, dimensions, and connections

Calibra Cool Technical Specifications and Dimensions

Presents detailed physical dimensions and technical specifications of the Calibra Cool unit.

List of Included Components in Delivery

Lists all components included in the product delivery package.

Transportation, space, and location

Heat Pump Transportation Guidelines and Precautions

Covers safe transportation methods, tilt limits, and handling precautions for the unit.

Recommended Installation Space and Location

Advises on optimal placement, clearance, and environmental considerations for installation.

Heating connections

Diagram for Calibra Cool Heating System Connections

Details the hydraulic connections for the heating and hot water systems.

Brine connection

Brine Pipe Connection Options and Layouts

Shows different options for connecting brine pipes to the heat pump.

General Guidelines for Brine Pipe Connections

Provides essential information and tips for making secure brine pipe connections.

Brine Connection: Left Side Knock-out Method

Step-by-step guide for connecting brine pipes via the left-side knock-out holes.

Brine Connection: Right Side Knock-out Method

Step-by-step guide for connecting brine pipes via the right-side knock-out holes.

Brine Connection: Top Knock-out Method

Step-by-step guide for connecting brine pipes via the top knock-out holes.

Sensors and power supply

Overview of Sensor and Power Supply Requirements

Outlines the general requirements for connecting sensors and the main power supply.

Outdoor Sensor Placement and Wiring Guide

Guides on the correct placement and wiring of the outdoor temperature sensor.

400V Power Supply Connection Requirements

Details the correct connection of the 400V three-phase power supply to the unit.

Installation of Optional External Reversing Valve

Explains how to connect an optional external reversing valve for cooling circuits.

Recommended Fuse Sizes for 400V Operation

Specifies the recommended fuse sizes and circuit breaker types for 400V operation.

Filling and bleeding

Procedure for Filling and Bleeding the Brine Circuit

Provides the procedure for filling and removing air from the brine circuit.

Commissioning

Gaining Installer Access to System Settings

Instructions on how to access advanced settings using the installer code.

Changing the Display Language Setting

Guides on how to change the language displayed on the unit's interface.

Configuring Date and Time Settings

Steps to set the correct date and time for the heat pump's operation.

Internal Immersion Heater Configuration Options

Configuration options for the internal immersion heater's operation.

Setting Heating Type: Radiator vs. Floor Heating

How to configure the system for floor heating or radiator systems.

Adjusting the Heat Curve for Optimal Performance

Method for adjusting the heat curve to match heating requirements.

Overview of Available Heating System Settings

Overview of settings like seasonal stop, min/max supply temperature, and comfort factor.

Adjusting Indoor Temperature in Heating Mode

How to easily adjust the desired indoor temperature via the comfort wheel.

Detailed Heating Settings and Curve Explanation

Further explanation of heating settings and their impact on climate.

Description of Display Symbols and Icons

Explains the meaning of various symbols displayed on the unit's interface.

Performing Manual System Tests

Steps to activate and run manual tests for system components.

Choosing the Heat Pump Operating Mode

Guide to selecting the desired operating mode (Heating, Cooling, Auto, Off).

Setting Up Remote Internet Monitoring (Thermia Online)

Instructions for connecting the heat pump to the internet for remote monitoring.

Enabling and Configuring Brine Monitoring Function

How to enable and configure the brine monitoring function for freeze protection.

Understanding and Handling System Alarms

Information on common alarms, their causes, and how to resolve them.

Activating and Configuring Cooling Mode (Standard)

How to activate and adjust cooling settings for standard models.

Cooling Configuration Without Room Sensor

Configuration for cooling operation when no indoor sensor is installed.

Cooling Configuration With Indoor Room Sensor

Configuration for cooling operation when an indoor sensor is installed.

Setting the Cooling Season Start Temperature

Setting the outdoor temperature threshold to start the cooling season.

Choosing Hot Water Production Modes (Economy, Normal, Comfort)

Options for selecting hot water production modes (Economy, Normal, Comfort).

Description of Display Symbols and Controls

Explains the meaning of display symbols and controls not covered elsewhere.

Additional functionality

Overview of Optional Heat Pump Features

Introduces the availability of extra features and accessories for the heat pump.

Activating and Configuring Additional Functions/Accessories

Guides on how to activate and configure additional accessories and functions.

Electrical connections

Calibra Cool 400V Electrical Wiring Diagram and Connections

Detailed diagrams and explanations of the 400V electrical connections for installation.

Related product manuals