Display | Digital |
---|---|
Operating Temperature | 15°C to 40°C |
Volume Range | 0.2 µL to 10 mL (depending on model) |
Autoclavable | Yes |
Tip Compatibility | Universal tips |
Material | PVDF and stainless steel |
Battery Life | Not applicable |
Calibration | ISO8655 |
Weight | Varies by model |
Increment | 0.1 µL |
Details the volume range covered by single and multichannel Finnpipette Digital models.
Explains the display shows the adjusted delivery volume on the handle.
Covers pipette materials and Finntip compatibility.
Defines intended use and general safety measures for pipette operation.
Highlights health risks, protective measures, and handling of materials.
Addresses factors affecting dispensing accuracy and material disposal.
Covers adjusting volume, using the tip ejector, and safety label.
Introduces general pipetting advice and specific methods like forward and reverse.
Details the step-by-step procedure for the forward pipetting technique.
Details the steps for pipetting heterogeneous samples, e.g., for blood glucose determination.
Explains factory calibration, re-adjustment principles, and testing requirements.
Lists ISO8655 calibration specifications for Finnpipette Digital Single Channel pipettes.
Lists ISO8655 calibration specifications for Finnpipette Digital Multichannel pipettes.
Lists specification limits for single and multichannel Finnpipette Digital pipettes.
Details the steps for adjusting the pipette volume.
Provides formulas for calculating results, including mass to volume conversion.
Covers short-term daily checks and long-term maintenance program development.
Details the step-by-step procedure for disassembling 0.2-50 µl pipettes.
Explains terms like evaporation loss, inaccuracy, and imprecision.
Provides step-by-step instructions for disassembling 50-1000 µl pipettes.
Provides step-by-step instructions for disassembling 1-10 ml pipettes.
Details the process for disassembling and reassembling multichannel pipettes.
Provides guidance on replacing tip cones for consistent multichannel performance.
Details the autoclaving process, cooling, and calibration checks post-sterilization.
Provides solutions for common issues like leakage, jamming, and dispensing errors.
Presents a table of conversion factor Z values based on temperature and air pressure.
Lists part numbers for various Finnpipette Digital single and multichannel models.
Lists product codes, Finntip types, and volume ranges for ordering.
Lists product codes for Finntip Filter tips and their corresponding volume ranges.