Page #1 background image
IEC
Instructions for use
MICROCL 17/17R 21/21R

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Thermo Scientific MicroCL 21R and is the answer not in the manual?

Thermo Scientific MicroCL 21R Specifications

General IconGeneral
Maximum Speed15, 000 rpm
Maximum Capacity24 x 1.5/2.0 mL tubes
Timer1 min to 99 min, continuous
Temperature RangeAmbient +5°C to 40°C
Dimensions (W x D x H)280 x 360 x 250 mm
Power Requirements50/60 Hz

Summary

Instructions for Use

Control Panel

For Your Safety

Safety Instructions in this Manual

Explains hazard symbols and general safety precautions.

Proper Use

Details the intended and correct usage of the centrifuge.

Improper Use

Describes unsafe practices and their consequences.

Centrifuging Hazardous Materials

Guidelines for centrifuging hazardous substances.

Handling the Centrifuge

General rules for operating the centrifuge safely.

Description of the Instrument

Safety Systems

Details the safety features integrated into the instrument.

Before Use

Where to Install the Centrifuge

Specifies suitable locations and environmental conditions for installation.

Transport and Installation the Centrifuge

Provides instructions for safe transport and physical installation.

Handling the Rotor

Aerosol-tight Application

Instructions and precautions for aerosol-tight operation.

Checking for Aerosol-tightness

Procedure to verify the aerosol-tight containment of the rotor.

Operation

Installing the Rotor

Step-by-step guide for installing a rotor into the centrifuge.

Loading the Rotor

Guidance on rotor loading capacity and preventing overload.

Placing the Tubes in the Rotor

Instructions for symmetrical and balanced loading of tubes.

Starting the Centrifuge

Steps to initiate a centrifugation run.

Stopping the Centrifuge

Procedures for stopping the centrifuge, including preset time and continuous runs.

Removing the Rotor

Procedure for safely removing the rotor.

Maintenance and Care

Disinfection

Procedures for disinfecting the centrifuge after contamination.

Autoclaving

Guidelines and limitations for autoclaving rotors and accessories.

Troubleshooting

Mechanical Emergency Lid Release

Procedure for manually opening the lid in emergencies.