Thermo Scientific
Orion Star A210 Series
Electrochemistry Benchtop Meters
68X000441 Revision A June 2015
User Manual

Table of Contents

Other manuals for Thermo Scientific Orion Star A215

Questions and Answers:

Thermo Scientific Orion Star A215 Specifications

General IconGeneral
pH Resolution0.01 pH
pH Accuracy±0.01 pH
mV Range-2000 to 2000 mV
mV Resolution0.1 mV
mV Accuracy±0.2 mV
Temperature Range-5.0 to 105.0 °C
Temperature Resolution0.1 °C
Temperature Accuracy±0.5 °C
Conductivity Accuracy±1% of reading
DisplayLCD
Data LoggingYes
Calibration PointsUp to 5 points
Communication InterfaceUSB
Salinity Range0 to 70 ppt
Power Supply4 AA batteries
Weight400 g

Summary

Meter Introduction

Meter Overview

Provides an overview of the Thermo Scientific Orion Star A210 series benchtop meters' features and capabilities.

Packing List

Lists the items included with the Orion Star A210 series benchtop meters and kits.

Intended Use

Specifies the intended use of the meter and warns against misuse that could invalidate warranty.

Meter Basics

Using the Universal Power Adapter

Instructions for connecting and using the included universal power adapter for meter operation.

Installing Batteries

Step-by-step guide for installing AA batteries as an optional power source for the meter.

Attaching the Electrode Stand and Holder

Procedure for attaching the electrode stand and holder to the meter for convenient electrode placement.

Using the Electrode Holder

Details on how to use the electrode holder in the stand for various electrode types.

Meter Connections

Diagram and description of all possible meter connections for Orion Star A210 series.

Meter Keypad

Explanation of the meter's keypad layout, function keys, and shortcut keys.

Function Keys

Details on the function keys (f1, f2, f3) and their specific actions on the meter display.

Meter Display

Examples and explanations of measurement display screens for various Orion Star A210 models.

Measurement Display Icons

Descriptions of various icons that appear on the meter's measurement display.

pH Electrode Condition Icon

Explanation of the pH electrode condition icon and its relation to electrode slope and stability.

Meter Models and Measurement Capabilities

Table showing available Orion Star A210 meter models and their measurement capabilities.

Meter Maintenance

Guidelines for routine cleaning and maintenance of the Orion Star A210 series meters.

Meter Setup Menus

Main Setup Menu

Overview of the main setup menu, including measurement, instrument, calibration, and diagnostic settings.

General Setup Menu Navigation

Instructions on how to navigate through the setup menus and select/enter values.

Main Setup Menu Icons and Descriptions

Descriptions of icons within the main setup menu and their applicable meter models.

Main Setup Menu Flow Chart

Visual flow chart illustrating the structure of the main setup menu options.

Channel-specific Mode and Settings Menu Flow Chart

Flow chart detailing the mode and settings options for each specific measurement channel.

Channel-Specific Method, Mode and Temperature Menus

Explanation of channel-specific menus for customizing measurement, calibration, and alarm settings.

Method Menu

Details on creating, loading, copying, editing, or deleting custom measurement methods.

Loading a Method

Instructions on how to activate a protected method for use in measurement mode.

Copying a Method

Procedure for saving existing method settings to a new method, allowing modifications.

Editing or Deleting a Method

Guide to modifying channel-specific settings of an existing method or converting it to open.

Mode and Settings Menu

General options for the Mode and Settings menu, including Read Types and Stability.

Read Types

Explanation of Auto-Read, Continuous, and Timed read types for measurements.

Stability Setting Information

Information on how the stability setting determines measurement stability and response time.

Averaging Setting

Options for selecting automatic smart averaging or disabling averaging for measurement stability.

Limit Alarm Setting

Configuration of high and low limit alarms to trigger alerts based on measurement values.

Calibration Due Alarm Setting

Setting a custom interval for calibration due alarms to remind users of recalibration.

Mode and Settings Menu for pH Channel

Customization of measurement, calibration, and alarm settings for the pH channel.

Buffer Group Setting

Details on buffer groups for automatic recognition during pH calibrations.

Testing a pH Electrode for Automatic Buffer Recognition

Procedure to verify pH electrode capability for automatic buffer recognition.

Mode and Settings Menu for pH/ISE Channel

Customization of measurement, calibration, and alarm settings for the pH/ISE channel.

Blank Correct Setting

Option to use blank correction for ISE measurements to compensate for non-linearity.

Low Level Stability Setting

Feature to improve accuracy of low concentration ISE measurements by adjusting stabilization time.

Mode and Settings Menu for COND Channel

Customization of measurement, calibration, and alarm settings for the conductivity channel.

Cell K Setting

Details on entering the nominal cell constant (K) for conductivity sensor calibration.

Reference Temperature, Temperature Compensation and Coefficient Settings

Options for temperature compensated conductivity measurements.

Salinity Type Setting

Selection between practical salinity and natural sea water for salinity measurements.

TDS Factor Setting

Setting the TDS factor to estimate dissolved inorganic material from conductivity readings.

Cell Type Setting

Option to set the conductivity sensor type as Standard or USP.

Mode and Settings Menu for DO/RDO Channel

Customization of measurement, calibration, and alarm settings for the DO/RDO channel.

Barometric Pressure Compensation Setting

Setting for automatic or manual barometric pressure compensation for DO measurements.

Salinity Correction Setting

Automatic salinity correction for dissolved oxygen readings based on manual salinity entry.

Temperature Menu

Customizing temperature settings: value, units, and calibration for each channel.

Manual Temperature Value

Instructions to manually enter a sample temperature value for meter settings.

Temperature Unit

Procedure to select temperature units as Celsius (°C) or Fahrenheit (°F).

Temperature Calibration

Procedure for calibrating the temperature sensor to improve accuracy.

Temperature Input

Setting the dissolved oxygen sensor's built-in temperature as the input source for measurements.

Instrument Settings Setup Menu

Updating meter settings for data transfer, data log, date/time, language, and display.

Log View Menu

Accessing and managing the meter's data log and calibration log.

Data Log

Information on the meter's 2000-point data log, including how points are saved and exported.

Calibration Log

Details on the meter's ability to save up to ten recent calibrations per channel.

Diagnostics Menu

Initiating meter reset, electrode stability tests, self-tests, and viewing meter information.

Meter Self Test Procedure

Procedure for performing a meter self-test to check accuracy.

Meter Verification Procedure

Procedure to verify meter accuracy for pH and pH/ISE channels using a shorting cap.

Electrode Stability Test Procedure

Testing the stability of an electrode by measuring input reading drift and noise.

Using the pH or pH/ISE Channel

Meter and Electrode Preparation

Instructions for preparing the meter and electrodes for pH or pH/ISE measurements.

pH Calibration Procedure

Step-by-step guide for performing a pH calibration using up to five pH buffers.

pH Calibration Editing

Option to edit or delete individual calibration points after initial calibration.

ORP Calibration Procedure (Relative mV Mode)

Procedure for performing an ORP calibration in the relative mV mode.

ORP Calibration Procedure (EH Units)

Procedure for performing a one-point ORP calibration to the EH value.

ISE Calibration Procedure

Guide for calibrating ion concentration using one to five standards.

ISE Calibration Editing

Option to edit or delete individual ISE calibration points.

Measurement Procedure

Instructions for performing measurements after electrodes are calibrated and prepared.

Using the Conductivity Channel

Meter and Sensor Preparation

Instructions for preparing the meter and conductivity sensors for measurement.

Conductivity Calibration Procedure

Step-by-step guide for calibrating the conductivity sensor using standards or cell constant.

Conductivity Calibration Editing

Option to edit or delete individual conductivity calibration points.

Alternative Certified Cell Constant Entry Calibration Procedure

Procedure for calibrating by manually entering the certified cell constant value.

Conductivity Standards vs. Temperature Table

Table showing conductivity standard values at different temperatures.

Conductivity Meter Verification Procedure

Procedure to verify conductivity measurement accuracy using calibration resistors.

Measurement Procedure

Instructions for performing conductivity measurements after sensors are prepared and calibrated.

Using the DO/RDO Channel

Meter and Sensor Preparation

Instructions for preparing the meter and dissolved oxygen sensors for measurement.

Dissolved Oxygen Calibration Procedure

Overview of the different dissolved oxygen calibration methods: Air, Water, Manual, Set Zero.

Air (Water-saturated Air) Calibration

Procedure for calibrating dissolved oxygen using air (water-saturated air).

Water (Air-saturated Water) Calibration

Procedure for calibrating dissolved oxygen using water saturated with air.

Manual (Winkler) Calibration

Procedure for calibrating dissolved oxygen using a manual (Winkler) titration method.

Set Zero Calibration

Procedure to set a zero point calibration for dissolved oxygen measurements.

Measurement Procedure

Instructions for performing dissolved oxygen measurements after sensors are prepared and calibrated.

Data Transfer and Software Updates

Data Storage and Transfer Settings

Settings affecting data storage and transfer: read type, export, data log, date/time.

Measurement Read Type Setting

Selection of Auto-Read, Continuous, or Timed read types for data logging and export.

Data Log Setting

Instructions to turn on the data log feature to save up to 2000 measurement sets.

Export Data Settings

Configuration of data export settings for transferring data to a computer or printer.

Printer Compatibility and Requirements

Information on printer compatibility and requirements for direct printing from the meter.

Computer Compatibility and Requirements

Requirements for computer compatibility, including OS, .NET framework, and interface cables.

Using the USB-to-Serial Computer Cable

Instructions for connecting the meter to a computer using a USB-to-Serial cable and driver installation.

Using the USB Computer Cable

Instructions for connecting the meter to a computer using a USB cable and installing drivers.

Orion Star Com Communication Software

Details on the Orion Star Com software for data transfer, export, and printing.

Meter Interfacing with Other Computer Programs

Connecting the meter to computer programs that use COM ports, like HyperTerminal.

Star A200-A300 Meter Remote Control Protocols

Rules and protocols for using remote control commands with the meter.

Star A200-A300 Meter Remote Control Commands

List and descriptions of available remote control commands for the meter.

Meter Software Upgrade Procedure

Instructions for downloading and installing software updates for the meter.

Customer Services

Troubleshooting Tips

Common issues encountered with the meter and recommended actions for resolution.

Meter Factory Reset Procedure

Procedure to reset all meter settings to factory defaults, erasing data logs.

Meter User Reset Procedure

Procedure to reset channel-specific and instrument settings to factory defaults.

Notice of Compliance

Statements regarding radio frequency energy, FCC rules, and Canadian Department of Communications regulations.

WEEE Compliance

Information on compliance with the European Union's Waste Electrical & Electronic Equipment Directive.

Declaration of Conformity

Declaration stating conformity with EMC and safety directives and standards.

Meter Specifications

Technical specifications for the Orion Star A210 series benchtop meters and operating conditions.

Orion Star A211 pH Benchtop Meter Specifications

Detailed specifications for the Orion Star A211 pH Benchtop Meter.

Orion Star A212 Conductivity Benchtop Meter Specifications

Detailed specifications for the Orion Star A212 Conductivity Benchtop Meter.

Orion Star A213 RDO/DO Benchtop Meter Specifications

Detailed specifications for the Orion Star A213 RDO/DO Benchtop Meter.

Orion Star A214 pH/ISE Benchtop Meter Specifications

Detailed specifications for the Orion Star A214 pH/ISE Benchtop Meter.

Orion Star A215 pH/Conductivity Benchtop Meter Specifications

Detailed specifications for the Orion Star A215 pH/Conductivity Benchtop Meter.

Orion Star A216 pH/RDO/DO Benchtop Meter Specifications

Detailed specifications for the Orion Star A216 pH/RDO/DO Benchtop Meter.

Ordering Information

Catalog numbers and descriptions for Orion Star A210 series meters and kits.

Meter Accessories, Electrodes and Solutions

Catalog numbers and descriptions for meter accessories, electrodes, and solutions.

Related product manuals