Thermo Scientific
Orion Star A210 Series
Electrochemistry Benchtop Meters
68X000441 Revision A June 2015
User Manual

Table of Contents

Other manuals for Thermo Scientific Orion Star A214

Questions and Answers:

Thermo Scientific Orion Star A214 Specifications

General IconGeneral
Temperature Accuracy±0.1 °C
Communication InterfaceUSB
pH Resolution0.01 pH; 0.1 pH
mV Range±2000.0 mV
mV Resolution0.1
mV Accuracy±0.2
Temperature Range-5.0 to 105.0°C
Temperature Resolution0.1°C
Conductivity Resolution0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 1 μS/cm
Salinity Range0.0 to 80.0 ppt
DisplayLCD
Calibration PointsUp to 5 points
Power4 AA batteries

Summary

Meter Introduction

Meter Overview

Provides an overview of the Thermo Scientific Orion Star A210 series benchtop meters, highlighting their features.

Packing List

Lists the items included with the Orion Star A210 series benchtop meters and meter kits.

Intended Use

Specifies the intended use of the meter and warns against misuse.

Meter Basics

Using the Universal Power Adapter

Instructions on how to connect and use the universal power adapter for the meter.

Installing Batteries (Optional Power Source)

Step-by-step guide on how to install AA batteries as an optional power source.

Attaching the Electrode Stand and Holder

Instructions on how to attach the electrode stand and holder to the meter.

Using the Electrode Holder

Details on how to use the electrode holder for easy movement of electrodes.

Meter Connections

Diagram and table showing available meter connections and their functions.

Meter Keypad

Description of the meter keypad, function keys, and their operations.

Function Keys

Explains the function keys (f1, f2, f3) and their corresponding actions shown on the display.

Meter Display

Examples of measurement display screens for different meter models.

Measurement Display Icons

Explains various icons displayed on the meter screen and their meanings.

pH Electrode Condition Icon

Explains the pH electrode condition icon and its status indicators.

Meter Models and Measurement Capabilities

Table showing available Orion Star A210 series meter models and their measurement capabilities.

Meter Maintenance

Provides basic guidelines for routine meter maintenance.

Meter Setup Menus

Main Setup Menu

Overview of the main setup menu for measurement, instrument, calibration, and diagnostics settings.

General Setup Menu Navigation

Step-by-step guide on how to navigate through the setup menus.

Main Setup Menu Icons and Descriptions

Explains the icons used in the main setup menu and their applicable meter models.

Main Setup Menu Flow Chart

Visual representation of the main setup menu structure and options.

Channel-specific Mode and Settings Menu Flow Chart

Flow chart detailing the mode and settings options for each channel.

Channel-Specific Method, Mode and Temperature Menus

Explains the purpose of Method, Mode and Settings, and Temperature submenus for channels.

Method Menu

Details on saving, creating, and managing custom measurement methods.

Loading a Method

Instructions on how to activate a protected method for use in measurement mode.

Copying a Method

Steps to save existing method settings to a new method.

Editing or Deleting a Method

Procedures for modifying or deleting channel-specific methods.

Mode and Settings Menu

General options for Mode and Settings, including Read Types and Stability.

Averaging Setting

How to set averaging for measurement stability or turn it off.

Limit Alarm Setting

Setting high and low limits to trigger alarms during measurements.

Calibration Due Alarm Setting

Setting a custom interval for calibration due alarms.

Mode and Settings Menu for pH Channel

Customization of measurement, calibration, and alarm settings for the pH channel.

Buffer Group Setting (pH)

How the meter recognizes pH buffer values during calibration.

Testing a pH Electrode for Automatic Buffer Recognition

Procedure to verify pH electrode capability for automatic buffer recognition.

Mode and Settings Menu for pH/ISE Channel

Customizing settings for pH/ISE channel measurements, calibration, and alarms.

Blank Correct Setting

Using blank correction for ISE measurements to compensate for non-linearity.

Low Level Stability Setting

Feature to improve accuracy in low concentration ISE measurements by adjusting stabilization time.

Mode and Settings Menu for COND Channel

Customizing measurement, calibration, and alarm settings for the conductivity channel.

Cell K Setting

Entering the nominal cell constant (K) value for conductivity sensors.

Reference Temperature, Temperature Compensation and Coefficient Settings

Options for temperature compensated conductivity measurements and their settings.

Salinity Type Setting

Choosing between practical salinity and natural sea water for measurements.

TDS Factor Setting

Setting the TDS factor to estimate dissolved inorganic material.

Cell Type Setting

Setting the conductivity sensor type as standard or USP.

Mode and Settings Menu for DO/RDO Channel

Customizing measurement, calibration, and alarm settings for the DO/RDO channel.

Salinity Correction Setting

Performing automatic salinity correction for dissolved oxygen readings.

Temperature Menu

Customizing temperature settings, units, and calibration for each channel.

Manual Temperature Value

Entering a manual temperature value for measurements.

Temperature Unit

Selecting temperature units (°C or °F).

Temperature Calibration

Procedure for calibrating ATC probes, conductivity sensors, or DO sensors.

Temperature Input

Setting the temperature input source for measurements on specific models.

Instrument Settings Setup Menu

Updating meter settings for data transfer, data log, date/time, language, etc.

Log View Menu

Accessing the data log and calibration log.

Data Log

Details on the meter's 2000-point data log and how data is saved.

Calibration Log

Information on saving and viewing the last ten calibrations per channel.

Diagnostics Menu

Options for meter reset, electrode stability test, self test, and viewing meter info.

Meter Self Test Procedure

Steps to perform a meter self-test to check accuracy.

Electrode Stability Test Procedure

Procedure to test the stability of an electrode by measuring input drift and noise.

Using the pH or pH/ISE Channel

Meter and Electrode Preparation

Steps for preparing the meter and electrodes for pH or pH/ISE measurements.

pH Calibration Procedure

Step-by-step guide for performing a pH calibration using up to five buffers.

pH Calibration Editing

How to fix individual calibration points without a full recalibration.

ORP Calibration Procedure (Relative mV Mode)

Procedure for ORP calibration in relative mV mode using one standard.

ORP Calibration Procedure (EH Units)

Procedure for ORP calibration to the EH value using specific standards.

ISE Calibration Procedure

Steps for calibrating ion concentration using one to five standards.

ISE Calibration Editing

Editing or deleting individual ISE calibration points.

Measurement Procedure

General steps for performing measurements using the pH or pH/ISE channel.

Using the Conductivity Channel

Meter and Sensor Preparation

Steps for preparing the meter and conductivity sensors.

Conductivity Calibration Procedure

Step-by-step guide for conductivity calibration using standards or cell constant entry.

Conductivity Calibration Editing

Editing individual conductivity calibration points.

Alternative Certified Cell Constant Entry Calibration Procedure

Procedure to calibrate by entering the certified cell constant (K) value.

Conductivity Standards vs. Temperature Table

Table showing conductivity standard values at different temperatures.

Conductivity Meter Verification Procedure

Procedure to verify conductivity measurement accuracy using resistors.

Measurement Procedure

General steps for performing measurements using the conductivity channel.

Using the DO/RDO Channel

Meter and Sensor Preparation

Steps for preparing the meter and dissolved oxygen sensors.

Dissolved Oxygen Calibration Procedure

Overview of the different dissolved oxygen calibration methods available.

Air (Water-saturated Air) Calibration

Procedure for calibrating dissolved oxygen using water-saturated air.

Water (Air-saturated Water) Calibration

Procedure for calibrating dissolved oxygen using air-saturated water.

Manual (Winkler) Calibration

Procedure for manual dissolved oxygen calibration using Winkler titration.

Set Zero Calibration

Procedure for performing a zero calibration for dissolved oxygen.

Measurement Procedure

General steps for performing dissolved oxygen measurements.

Data Transfer and Software Updates

Data Storage and Transfer Settings

Settings affecting data storage and transfer, including read type and data log.

Measurement Read Type Setting

Setting the read type (Auto-Read, Continuous, Timed) for measurements.

To Set Measurement Read Type

Step-by-step guide to set the measurement read type.

Data Log Setting

Turning the data log function on to save measurements.

Export Data Settings

Configuring settings for exporting data to a printer or computer.

Printer Compatibility and Requirements

Information on printers compatible with the meter and required settings.

Computer Compatibility and Requirements

Requirements for computer compatibility and connection cables.

Using the USB-to-Serial Computer Cable

Instructions for connecting and using the USB-to-Serial cable.

Using the USB Computer Cable

Instructions for installing drivers and connecting using a USB cable.

Orion Star Com Communication Software

Details about the Star Com software for data transfer and its requirements.

Meter Interfacing with Other Computer Programs

Connecting the meter to other computer programs using COM ports.

Star A200-A300 Meter Remote Control Protocols

Rules for remote control usage and communication settings.

Star A200-A300 Meter Remote Control Commands

List and description of commands for remote meter control.

Meter Software Upgrade Procedure

Steps to upgrade the meter's software using a computer.

Customer Services

Troubleshooting Tips

Common meter issues and recommended actions to resolve them.

Meter Factory Reset Procedure

Steps to reset all meter settings to factory defaults.

Meter User Reset Procedure

Steps to reset channel-specific and instrument settings to defaults.

Notice of Compliance

Compliance statements regarding FCC Rules and Canadian regulations.

WEEE Compliance

Information on compliance with the EU Waste Electrical & Electronic Equipment Directive.

Declaration of Conformity

Declares conformity with EMC and Safety standards for the meter models.

Meter Specifications

Lists operating conditions, dimensions, power, and general meter specs.

Orion Star A211 pH Benchtop Meter Specifications

Detailed specifications for the Orion Star A211 pH meter.

Orion Star A212 Conductivity Benchtop Meter Specifications

Detailed specifications for the Orion Star A212 Conductivity meter.

Orion Star A213 RDO/DO Benchtop Meter Specifications

Detailed specifications for the Orion Star A213 RDO/DO meter.

Orion Star A214 pH/ISE Benchtop Meter Specifications

Detailed specifications for the Orion Star A214 pH/ISE meter.

Orion Star A215 pH/Conductivity Benchtop Meter Specifications

Detailed specifications for the Orion Star A215 pH/Conductivity meter.

Orion Star A216 pH/RDO/DO Benchtop Meter Specifications

Detailed specifications for the Orion Star A216 pH/RDO/DO meter.

Ordering Information

Catalog numbers and descriptions for meters and kits.

Meter Accessories, Electrodes and Solutions

Catalog numbers and descriptions for meter accessories, electrodes, and solutions.

Related product manuals