TVA2020
Instruction Manual
Toxic Vapor Analyzer
Part Number 111755-00
29Jul2014
Question and Answer IconNeed help?

Do you have a question about the Thermo Scientific TVA2020 and is the answer not in the manual?

Thermo Scientific TVA2020 Specifications

General IconGeneral
TypeToxic Vapor Analyzer
Detection MethodFlame Ionization Detector (FID) and Photoionization Detector (PID)
Power SupplyRechargeable Lithium-ion battery
AlarmsAudible and visual alarms
Measurement PrincipleIonization
PID Range2, 000 ppm
Detection Range0.1 to 2, 000 ppm (PID)
Response Time<3 seconds
Data LoggingYes, internal memory
Wireless CommunicationBluetooth
Battery Life8 hours

Summary

Safety and Equipment Damage Alerts

Safety and Equipment Damage Alerts in this Manual

Lists specific warnings related to battery, charger, and instrument operation.

Chapter 1 Introduction

Concentration Calculation and Calibration

Details the process of converting detector counts to concentration.

Standard Specifications

Lists detailed technical specifications including accuracy, repeatability, and range.

Chapter 2 Hardware and Startup

Instrument Functions

Describes the four operational modes: RUN, SETUP, INFO, MEMORY.

Control Menu

Menu for controlling pump, FID, PID, Bluetooth, and GPS functions.

Quick Start Procedure

Step-by-step guide for initial setup and operation.

Chapter 3 Display Menus

Calibration Settings

Accessing and customizing instrument calibration settings.

Alarm Levels

Describes STEL, Low Ceiling, and High Ceiling alarm types.

Chapter 4 Calibration

Calibration Configuration

Customizing calibration settings like span points, concentration, and correction.

Defining the Response Factor

Adjusting analyzer readings for different compounds using correction factors.

Chapter 5 Preventive Maintenance

Safety Precautions

Essential safety measures before performing maintenance procedures.

Hydrogen Gas Tank

Details on handling and maintaining the hydrogen gas supply.

Chapter 6 Troubleshooting

Troubleshooting Guide

Provides a guide for diagnosing and resolving instrument problems.

Warning Messages

Lists and explains error and warning messages displayed by the TVA2020.

Chapter 7 Servicing

Replacement Parts List

Lists major subassemblies and part numbers for the TVA2020.

Opening the Instrument

Procedure to gain access to the internal components of the instrument.

Replacing the Battery

Procedure for removing and replacing the instrument's battery.

Servicing the Pump

Procedures for removing, accessing, and replacing pump components.

Flow Tests

Procedures for checking instrument flow and diagnosing problems.

Leak Check

Procedure for verifying the absence of leaks in the system.

Appendix C Response Factors

Response Factor Multiplier

Explains the most common response factor format used by TVA2020.