Analyze Detect Measure Control
IEC Centra CL3 Series
Centrifuges
OM3750 Rev. 5 11 January 2004
VENTILATED
Cat. No.3750: 120 VAC, 60Hz
REFRIGERATED
Cat. No.3755: 120 VAC, 60Hz
Operation Manual
Cat. No.3751: 220, 230, 240 VAC, 50/60 Hz
Cat. No.3756: 220, 230, 240 VAC, 50 Hz
Cat. No.3757: 230 VAC, 60 Hz
®
Question and Answer IconNeed help?

Do you have a question about the Thermo IEC Centra CL3 and is the answer not in the manual?

Thermo IEC Centra CL3 Specifications

General IconGeneral
BrandThermo
ModelIEC Centra CL3
CategoryLaboratory Equipment
LanguageEnglish

Summary

Introduction

Product Description

Describes IEC Centra CL3 Series units, models (Ventilated, Refrigerated), and capabilities.

About This Manual

Outlines the manual's content, covering installation, operation, and maintenance of the centrifuges.

Installation

Receiving the Unit

Instructions for unpacking, inspecting, and completing warranty for the centrifuge upon delivery.

Preparing the Installation Site

Guidelines for selecting a suitable location, including level surface and ventilation clearance.

Verifying Power Configuration

Ensures correct power cord and grounded supply for safe and optimal operation.

Circuit Breaker

Explains the function of the automatic circuit breaker for protection against power surges.

Moving the Unit

Procedures for safely relocating the centrifuge, including disengaging suction cups.

Operation

Rotor and Accessories

Details on loading, balancing, and installing rotors for vibration-free operation.

Starting and Stopping a Run

Step-by-step guide for initiating and terminating centrifugation cycles.

Timing Mode

Explains the different timing options available for centrifugation runs.

Stored Programs

How to save, recall, lock, and unlock custom run parameters.

Refrigeration

Specific instructions for operating the temperature control on refrigerated models.

Front Panel

Overview of the centrifuge's control panel, displays, and keys.

Diagnostic Messages and Error Codes

Interpretation of beeps, warnings, and error messages for troubleshooting.

Applications

Introduction

An overview of the applications section and its reference materials.

Speed and Force Tables

Comprehensive tables listing rotor specifications, speeds, and RCF values.

Derating Tables for Dense Samples

Guidance on adjusting speed for samples with specific gravity above 1.2/1.5.

Chemical Resistance Table

Details on material compatibility with various laboratory chemicals.

Decontamination Table

Information on compatible sterilization methods for different materials.

RCF Nomograph

A tool for calculating Relative Centrifugal Force based on speed and radius.

Maintenance

Care and Cleaning

Procedures for daily cleaning, stain removal, and general upkeep.

Corrosion Cleaning Procedure

Steps to identify and remove corrosion from parts.

Storage: Keep the Unit Dry

Guidelines for proper storage to prevent damage and moisture.

Decontamination Procedures

Methods for decontaminating the unit and its components.

Cover Interlock Bypass

How to manually unlock the cover in case of power failure.

Condition of Returned Equipment

Requirements for returning equipment, including decontamination certification.