iCAP 6000 Series ICP-OES Spectrometer
Hardware Manual
©
2005 Thermo Electron Corporation Registration No. 441506 SOLAAR House, 19 Mercers
Row, Cambridge CB5 8BZ, United Kingdom. Telephone +44 (0) 1223 347400, Fax +44 (0) 1223
347402, http://www.thermo.com
Question and Answer IconNeed help?

Do you have a question about the Thermo iCAP 6300 and is the answer not in the manual?

Thermo iCAP 6300 Specifications

General IconGeneral
BrandThermo
ModeliCAP 6300
CategoryLaboratory Equipment
LanguageEnglish

Summary

Instrument Safety

iCAP 6000 Safety Guidelines

Guidelines for safe operation and maintenance of the iCAP 6000 instrument and accessories.

Safety Introduction

Instrument and accessories are for trained personnel; qualified engineers for maintenance.

General Safety Precautions

Essential procedures and symbols for correct and safe instrument use.

Electrical Safety Guidelines

Ensures safety by proper earthing and following national electrical regulations.

Equipment Cleaning and Decontamination

User responsibility for cleaning and decontamination if hazardous material is spilled.

Impaired Safety Protection Procedures

Inoperative instrument if safety protection is impaired; refer to service.

EC Declaration of Conformity

Spectrometer Installation

Sample Introduction System Assembly

Instructions for assembling standard sample introduction glassware, with safety warning.

Radial Torch Assembly Installation

Instructions for assembling the radial torch assembly components.

Sample Introduction System Setup

High Dissolved Solid Samples

HF Sample Introduction

Autosampler Use

Autosampler Installation Requirements

States that autosampler installation requires trained and certified Thermo Electron personnel.

Hydride Generation Systems

On-line Hydride Generation Kit

Describes the on-line hydride generation kit, its components, and function.

Hydride Generation Optimisation

Details plasma ignition and parameter settings for hydride generation optimisation.

Enhanced Hydride Generation Kit

Enhanced Hydride Kit Setup

Instructions for assembling the enhanced hydride generation accessory with the iCAP 6500.

Enhanced Hydride Optimisation

Guidance on optimizing parameters for the enhanced hydride generation kit.

Ultrasonic Nebuliser System

Ultrasonic Nebuliser Installation

States that ultrasonic nebuliser installation requires trained personnel.

Instrument Optimisation

Method Optimisation Parameters

Lists parameters affecting data and their optimization for analysis requirements.

SOP: Striking the Plasma

Procedure for igniting the plasma, checking interlocks, and stabilizing with a blank.

SOP: Running the Analysis

Guides on running blank and high standard calibrations and obtaining results.

Local Database Creation Steps

Creating a Database Connection

Attaching a Database to iTEVA

Procedure for attaching an existing database file to the iTEVA system.

Backing up Databases

Restoring a Database

Procedure for restoring a database from a backup file.

Instrument Maintenance

Sample Introduction System Cleaning

Importance of maintaining the sample introduction system for accurate results.