Thermo Spectronic GENESYS 6 User Manual

Default Icon
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image

Table of Contents

Questions and Answers:

Thermo Spectronic GENESYS 6 Specifications

General IconGeneral
TypeUV-Visible Spectrophotometer
Wavelength Range190 - 1100 nm
DetectorSilicon Photodiode
Light SourceTungsten Halogen and Deuterium
DisplayLCD
ConnectivityRS-232
Power Requirements100-240 V, 50/60 Hz

Summary

General Safety Notes

Safety Symbols Explained

Explains warning symbols used in the manual for user safety.

Chapter 2 Inspection and Performance Checklist

Inspection/Performance Checklist

A checklist for field inspection and performance verification of the instrument.

Chapter 3 Troubleshooting Guide

Initialization Sequence

Steps for the instrument's startup initialization sequence.

Troubleshooting Chart

Table listing symptoms, probable causes, and corrective actions.

Chapter 4 Routine Maintenance

Tungsten Lamp Replacement

Step-by-step guide for replacing the tungsten lamp safely.

Chapter 5 Disassembly and Replacement

External Covers Removal

Safety precautions and steps for removing external covers.

Power Supply Replacement

Safety precautions and steps for replacing the instrument's power supply.

Main (CPU) Circuit Board Replacement

Instructions for removing and replacing the main CPU circuit board.

Chapter 6 Optical Alignment

Alignment Sequence

Procedure for aligning optical components using specific tools.

Beam Alignment with Microcell

Procedure for aligning the beam path using a microcell.

Chapter 9 Service Diagnostics Software

Port Open Error Troubleshooting

Troubleshooting messages and causes for communication port errors.

Connection Error Troubleshooting

Common causes for failure to establish instrument connection.

Reset Spectronic GENESYS 10

Procedure for performing a full power-up reboot sequence.

Calibrate Instrument

Steps for performing wavelength calibration, including filter requirements.

Wavelength Calibration Window

Interface for setting and performing wavelength calibration.

Alignment Tool Utility

Utility to check limit switches and set zero order before mirror alignment.

Seek Zero Order

Procedure to check and adjust the zero order position of the light beam.

Flash Xenon Lamp

Control to flash the Xenon lamp for optical alignment procedures.

Detector Board Diagnostic

Tool to test detector operation and adjust gain settings.

Chapter 10 RS232 Commands

Data Commands

RS232 commands for acquiring ABS, CONC, TRANS, and UNIT data.

Instrument Control Commands

Commands for controlling grating wavelength and turret position.

Chapter 11 Technical Support Bulletins

TSB S-400: Upgrade to Flashable EEPROM

Procedure for upgrading instrument firmware via EEPROM replacement.

EEPROM Replacement (Firmware Rev. 1.030 and earlier)

Detailed steps for physically replacing the instrument's ROM IC.