Orion Star
Series Meter
User’s Guide
Analyze
Detect
Measure
Control

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Thermo Orion Star and is the answer not in the manual?

Thermo Orion Star Specifications

General IconGeneral
pH Range0.00 to 14.00 pH
pH Resolution0.01 pH
pH Accuracy±0.01 pH
mV Resolution0.1 mV
mV Accuracy±0.2 mV
Temperature Resolution0.1 °C
Temperature Accuracy±0.1 °C
Data LoggingYes
Parameters MeasuredpH, mV, Conductivity, Dissolved Oxygen, Temperature, ISE
mV Range±2000.0 mV
Dissolved Oxygen Resolution0.1 mg/L
Temperature Range-5.0 to 105.0 °C
ISE Accuracy±0.01 pX
DisplayLCD with backlight
ConnectivityUSB
PowerBattery or AC adapter

Summary

Chapter I Introduction

Password Protected Methods

Secure custom measurements and calibrations with password protection.

Chapter IV Preparation

Connecting the Electrodes

Diagrams and explanations for connecting various probes and electrodes to the meter.

Chapter V Menu Setup

General Menu Settings

Configuration options for manual temperature compensation, stirrer speed, and auto-shutoff.

Continuous, Timed, or AUTO-READ™ Measurement Selection

Options for selecting measurement modes: continuous, timed, or automatic readings.

Setting Calibration

Guides on initiating and navigating through the calibration process for various measurement types.

Chapter VI Data Archiving and Retrieval

Chapter VII pH Technique

pH Setup

Configuration options for pH measurement, including resolution and buffer set selection.

pH Calibration for 1-5 Points

Detailed steps for performing pH calibration using 1 to 5 calibration points.

pH Measurements

Procedures for taking pH measurements in continuous, AUTO-READ™, or timed modes.

Chapter VIII Dissolved Oxygen Technique

Dissolved Oxygen Setup Options

Configuration settings for DO measurement, including resolution, pressure, and salinity compensation.

DO Setup Steps

Step-by-step guide for configuring Dissolved Oxygen measurement parameters.

DO Calibration

Procedures for probe preparation, polarization, and initiating DO calibration.

Calibrating with Water Saturated Air

Instructions for performing a DO calibration using water-saturated air.

Probe Zero Calibration

Procedure for zeroing the DO probe to compensate for residual current.

DO Measurements

How to take Dissolved Oxygen measurements in various modes.

Chapter IX Conductivity Technique

Conductivity Setup

Configuration options for temperature compensation, TDS factor, cell constant, and reference temperature.

Conductivity Calibration for 1-5 Points

Steps for performing conductivity calibration using 1 to 5 calibration points.

To Take a Conductivity Measurement

Procedures for taking conductivity measurements in different modes.

Chapter X ISE Technique

ISE Setup Options

Configuration settings for ISE measurement, including resolution, units, range, and auto-blank.

ISE Calibration for 1-5 Points

Detailed steps for performing ISE calibration using 1 to 5 calibration points.

ISE Measurement

Procedures for taking ISE measurements after calibration.

Chapter XI mV and ORP Technique

Chapter XIII Care and Maintenance

Error Codes & Debugging

Lists error codes, their descriptions, causes, and troubleshooting steps for the Orion Star Series meters.

Troubleshooting

General troubleshooting guidance for conductivity, dissolved oxygen, and ISE measurements.