14
Electric Tankless Instant Water Heater -
Installation Manual and User Guide
EN
Mounting Instructions
B12.
Inlet
Outlet
The appliance must be earthed properly!
The filter mat contained in accessory bag must be installed when connecting with
inlet(cold) water pipe or hose!
Earth leakage circuit breaker must be installed with the appliance, please take
page.17 to 27 for the selection of breaker.
Frost
The appliance is not to be installed in locations where freezing can occur.
The device should be installed in a vertical position in a room protected from frost and
in the proximity of the water connections�
In case the room cannot be protected against frost, the device should not be installed in
this room� Should the device be installed in such a room, the device should be emptied
before the frost danger will occur
Do not switch on if there is a possibility that the water in the device is frozen�
Commissioning
Install the device following the steps below�
Fill the device and vent it by opening a hot water tap connected to it�
Only switch on the electrical supply once the device is clear of any air
Check the operation of the device�