Chapter 7 ’Tools’ — HP Monitoring Tools (6RU and 10RU Devices)
190 ViBE VS7000
User Manual
5.
Set the Network Mode to
static
and press OK.
6.
Select Accept and press OK.
Figure 7-12. ViBE VS7000 front panel screen – Onboard Administrator IP address setting
7.
Use the arrows to enter the IP address in the OA1 IP field.
8.
Select Accept and press OK.
Once the IP address is set, you can access the equipment remotely.
1.
From a remote computer, type the IP address in the address bar.
2.
Enter the user name and password indicated on the asset tag.
You are now connected to the HP configuration interface.
Performing the IP Configuration from the HP
Interface
Once you are connected to the HP configuration interface, you can
perform a variety of settings, and particularly the settings of the
interconnect bays. What we call
interconnect bays
are the HP VC Flex-10
Enet Modules.
Accessing the Interconnect Bays’ Management Console
Before configuring the interconnect bays, make sure you write down the
user name and password of each module. They are indicated on the label
on the rear panel of the blade center.
To connect to the interconnect bay:
1.
From the tree menu on the left, select Enclosure Information,
Interconnect Bays and select a bay.

Table of Contents