EQUIPMENT: T1216W-C
PUBLICATION: MARINEW-P-I
ISSUE No. & DATE: 1 11/12
© 2012 Thorn Security Ltd PAGE 1 of 39
Registered Company: Thorn Security Ltd. Registered Office: Dunhams Lane Letchworth Garden City Hertfordshire SG6 1BE
TYCO T1216W-C
Marine
Fire Detection/Alarm Control Panel and Repeater
Installation and Commissioning Manual
Question and Answer IconNeed help?

Do you have a question about the Thorn security TYCO T1216W-C and is the answer not in the manual?

Thorn security TYCO T1216W-C Specifications

General IconGeneral
BrandThorn security
ModelTYCO T1216W-C
CategoryMarine Safety Device
LanguageEnglish

Summary

Introduction

Introduction

Manual provides installation, commissioning, and maintenance info for the T1216W panel.

Installation and Commissioning Overview

Install all field wiring and equipment

Steps for installing field wiring and connected equipment as per instructions.

Install the panel

Steps for installing the panel itself, without connecting field equipment.

Connect any repeaters (if applicable)

Instructions for connecting any required repeater units to the system.

Installation

Electrical Safety

Crucial safety precautions for installation to prevent damage and injury.

Important Notes on Batteries

Critical safety warnings and guidelines for handling and using batteries.

T1216W Panel Installation Instructions

Detailed steps for mounting and disassembling the T1216W panel enclosure.

Bulk Head mounting

Instructions for mounting the enclosure to a bulkhead.

Console mounting

Instructions for mounting the enclosure into a console.

Connection of the incoming AC Power Supply

How to connect the main AC power supply to the panel.

T1200B-C Battery Box Installation

Procedures for installing the T1200B-C battery box.

Battery Installation

Steps for physically placing batteries into the battery box.

Battery Connection

How to connect the battery leads and thermistor assembly.

Connecting the battery box to the panel PSU

Details on connecting the battery box to the panel's power supply unit.

Installation and connection of the C1631 Repeater Interface

Guide for installing and connecting the C1631 repeater interface board.

Installation and connection of the C1665 Muster Interface

Guide for installing and connecting the C1665 muster interface board.

Modifications to the Water Mist Relay Control Panel

Describes necessary modifications for interface with the WMRCP.

Modification 1 [System Abnormal]:

Details for modifying the panel for system abnormal conditions.

Modification 2 [System Operated]:

Details for modifying the panel for system operated conditions.

Modification 3: [Fault Input from T1216W-C]

Guide for adding a fault interface relay from the T1216W-C.

Interconnections with the Water Mist Relay Control Panel

Procedures for connecting the T1216W-C to the Water Mist Relay Control Panel (WMRCP).

Final Connections between the T1216W and WMRCP

Steps for making the final connections between the panels.

Replacing the Display Inserts

Instructions on how to change display inserts for user identification.

To change the inserts

Step-by-step guide for replacing display inserts on the panel.

To Fit the Optional Door Stay

Instructions for fitting an optional door stay for the panel enclosure.

Commissioning

Introduction

Lists required equipment for minimizing commissioning time.

Commissioning Checklist

Pre-commissioning checks for wiring, equipment, and documentation.

An Overview of the Commissioning Procedure

Outlines the three main stages of the commissioning process.

Pre-Commissioning Wiring Check

Detailed procedure for checking all wiring before system commissioning.

Powering up

Steps to safely power up the panel after installation and checks.

Intrinsically safe zone arrangement

Guidelines for configuring and installing intrinsically safe zones.

Basic Default Configuration

Describes the factory-set default configuration settings of the panel.

Vessel-Specific Configuration

How to tailor panel functionality to specific vessel needs.

Operating the Engineer's Functions

Engineer's Zone/Output Configuration Process

How to configure zones and outputs using DIL switches.

Zone or Output Configuration

Step-by-step guide for selecting and configuring zones or outputs.

To Restore the Factory Default Configuration for Zones & Outputs

Procedure to reset zone/output configurations to factory defaults.

Engineer's Zone/Output Configuration Time-out Warning

Warning about the time-out feature for configuration mode.

Invalid Configuration conditions

Explains conditions that lead to invalid panel configurations.

List of configuration DIL switches and their functions

Details the functions of various DIL switches for configuration.

List of Link Configuration features

Lists features configurable via link positions on the motherboard.

DIL switch settings on the Repeater Interface Board

Settings for the C1631 Repeater Interface board for quantity and address.

C1630 Output Interface Configuration

Configuration of the C1630 output expansion interface.

C1634 8 way volt free relay output module configuration

Configuration settings for the C1634 relay output module.

Commissioning Procedure

Guide for commissioning the panel's circuits after initial setup.

Alarm Circuits

Steps for commissioning alarm circuits, including testing sounders.

Zones

Procedures for testing zone fault and fire conditions.

Class Change Input

Notes that this is not a marine function.

Fire [Routing] Output

How to test the Fire [Routing] output signal.

Fault [Routing] Output

Reference to testing the Fault [Routing] Output.

Fire Protection Output

How to test the Fire Protection output for controlling equipment.

Ancillary inputs

Testing of remote silence, reset, and evacuate inputs.

Ancillary outputs

Testing of zone outputs, disablement, evacuate, and buzzer outputs.

Repeaters [when supplied]

Commissioning steps for repeater panels.

Repeater Muster link [if fitted]

Testing of the repeater muster link functionality.

Power Supply Unit

Checks and procedures related to the power supply unit.

T1216W-C – WMRCP Interface

Commissioning the interface between T1216W-C and WMRCP.

Final Dressing of the Cables

Ensuring field conductors are secure and tidy within the enclosure.

User Indications

General Indicator Section

Explains the meaning of general indicator LEDs on the panel.

Zone Location Indications

Details the indications for zone status, including fire and fault conditions.

User Controls

Access Controls Keyswitch

Explains the function of the keyswitch for accessing controls.

Button Functionality

Details the functionality of each button on the user interface.

PCB Layouts

C1627 Motherboard Layout

Diagram showing the layout of the main C1627 motherboard.

Rear Right Hand Side of Display PCB

Diagram showing the rear of the display PCB and its connectors.

C1634 Relay Output Module

Diagram of the C1634 relay output module and its connections.

C1630 Output Expansion Interface

Diagram showing the C1630 output expansion interface and its configuration switches.

C1631 Repeater Interface Board

Diagram of the C1631 repeater interface board and its configuration switch.

C1665 Muster Interface Board

Diagram of the C1665 muster interface board and its terminals.

Installation Details

BACKBOX MOUNTING DETAILS

Dimensions and details for mounting the backbox.

CONSOLE MOUNTING DETAILS

Dimensions and details for mounting the panel in a console.

REAR VIEW

Rear view dimensions, including cut-out and mounting holes.

TECHNICAL DATA

Key technical specifications like dimensions, weight, materials, and finish.

CABLE ENTRY

Details on cable entry points and wire sizes.

Wiring Diagrams

Mains AC Change-Over Unit Electrical Installation Diagram

Diagram showing the electrical installation of the mains AC change-over unit.

T1216W-C Panel

Wiring diagram for the T1216W-C panel, including mains terminal block.

Wiring Diagram Notes

Modification to Watermist Relay Control

Notes on modifications needed for the Watermist Relay Control.

Field Relay Specification

Specification details for field relays used in wiring.

Remote Inputs

Notes on connecting remote inputs like Silence Alarms and Evacuate.

Remote Outputs

Notes on connecting remote outputs like Disablement Active.

Fire Signal, Fault Signal & Fire Protection Output Specification

Specifications for fire, fault, and fire protection outputs.