9
Troubleshooting
TROUBLESHOOTING
The unit is not turning on
Check whether the unit has been turned on.
Check the power supply (try a different power source/vehicle/socket).
Check whether the plug and the socket have a good connection.
Check whether the fuse has been burned out or blown.
Low refrigeration performance
Too much product has been placed inside the unit.
There is too much warm product inside the unit.
The lid is unlatched or open.
The lid seal is broken.
Poor ventilation (allow 100mm of space around all vents).
The ambient temperature is too high.
The temperature setting is too high.
Can hear the sound of running water from inside the unit
This is normal, due to the flow of refrigerant in the unit.
Unusual noise when refrigerator is working
The refrigerator is not placed on a level surface.
If none of the above solves your issue please contact
Thunder at thunderauto.com.au or thunderauto.co.nz.
Yellow fault light flashing
ER 1 flash every 4 seconds - low voltage:
Try on different power source (vehicle or 240V AC power). If changing
power source fixed issue, then possible issue with original power source.
Ensure cabling between fridge and battery is at least 4mm, if the distance is
more than 2 metres then use at least 6mm cable.
ER 2 flashes every 4 seconds - fan issue:
Fan is drawing too many amps (over 0.5 amps), replace fan.
ER 3 flashes every 4 seconds - compressor start issue:
Unplug cable and allow unit to rest for 10 minutes.
Try on different power source (vehicle or 240V AC power).
Electronic box fault.
Compressor fault.
ER 4 flashes every 4 seconds - low motor speed:
Reduce products/items inside unit.
Move so unit is in a lower ambient temperature, clean vents/ensure clear air
flow over compressor.
Fan fault.
ER 5 flashes every 4 seconds - over temperature:
Ambient temperature too high.
Clean vents/ensure clear air flow over compressor.