ACCESSING LEVANTO
To access to Levanto you can use the serial port or the mobile interface. The access can be done by
using the RS232 serial port, configured in console mode (default configuration), using the included
cable and any terminal emulator. The default parameters to be set on the terminal, towards the
serial port, are:
Bits per second: 9600
Data Bits: 8
Parity: None
Stop bits: 1
To access via Ethernet interface:
Connect an Ethernet cross cable to the Levanto's interface
Connect the other end od the cable to the Ethernet pc card
Open Telnet application on the pc and connect to the module using:
IP address: 10.10.113.1
Netmask: 255.255.0.0
Broadcast: 10.10.255.25
Network address: 10.10.0.0
Welcome to the Tiesse LEVANTO router
LEVANTO login: root
No Radius configured. Using Local authentication
Password:
local: Authentication OK
Service Type is: Administrative-User
Idle timeout is set to 3600 seconds
Connected Users:
root
You are logged on ttyS2
root@LEVANTO>
After the module is turned on, the communication features could take some seconds, because the
various interfaces must be powered on and initialized.
You can log on to the module using the mobile interface via remote Telnet.
USERNAME AND PASSWORD
To log into Levanto you must specify the login and password:
The default factory configuration are:
Login: root
Password: tiesseadm
you can change the user password throught the cli ommand:
change_password root
this will require you to type the new password