Reassembly
of
Movement
(Model
33)
Carefully
orient the
dial
over
the assembly
and
then,
hold
ing the
dial
in place, turn the assembly
over
and
bend
the
four
tabs
to
secure
the
dial
to
the
Date
Frame.
TO
POSITION
HANDS
FOR
PROPER
DAY
AND
DATE
CHANGE
First
-Hold
watch assembly
with
mov
ement
side
up
and
crown
and
stem
at
three o'clock position. Pull
out
crown
and
stem.
Next
-Rotate
crown
and
stem
slowly
and
observe
date
lever
at
nine
o'clock position.
Date
lever
will
then begin
to
move
and
a click
will
be heard.
After
the click,
rotate
crown slowly until
date
lever snaps
back
.
At
this time stop
rotating
.
Fi
nally-Turn
assembly
over
and
replace
all
hands
at
12 o'clock position.
Check the
proper
function
of
the
bay
and
the Date change mechanism.
Loosen the set lever screw
and
remove the crown
and
stem
as
previously
noted on page 33.3. Position the Dial
and
Movement assembly in the
bezel, insert the crown
and
stem
through
the bezel
and
retighten the
set lever screw.
Reassemble the Retaining Spring as shown in Figure
2.
The
end
of
the
spring
should be inserted into the
groove
near
the stem
at
the
balance
wheel
end
of
the movement. Insert the rest
of
the spring into the
groove
being
careful
not
to
damage
the
balance
ass
embly
.
Reassemble the
rotor
assembly
by
sliding it into the movement
under
the rocker arm as shown
in
Figure 2. Secure the rotor
to
the movement
with
two
screws as shown in Figure 1.
Position the case
back
with the
'T'
on
"Timex"
toward
the crown
and
snap it into the bezel.
33.8