Others:
Sensors error:
Collector sensor (T1): The pump P1 is stopped (Err 1 and
concerning LED blinks).
Tank sensor (T2): The pump P1 is stopped (Err 2 and
concerning LED blinks).
Extra sensor (T3): The additional heat is stopped. (Err 3)
Corresponding value for sensor PT1000:
(To be check with an Ohmmeter, only when the sensor is
disconnected)
-10°C / -14°F 960 ohms
0°C / 32°F 1000 ohms
10°C / 50°F 1039 ohms
20°C / 68°F 1077 ohms
30°C / 86°F 1116 ohms
40°C / 104°F 1155 ohms
50°C / 122°F 1194 ohms
60°C / 140°F 1232 ohms
70°C / 158°F 1271 ohms
80°C / 176°F 1309 ohms
90°C / 194°F 1347 ohms
100°C / 212°F 1385 ohms
120°C / 248°F 1461 ohms
140°C / 284°F 1535 ohms