EasyManuals Logo

TiSUN SIMPLEX User Manual

TiSUN SIMPLEX
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
7
Parameter menu
First of all press (+) and (-) in the same time during 2 seconds to
enter in the parameter menu.
The first parameter of the list should be now displayed 1 
Press the navigation key to choose a parameter (>>), once the
parameter chosen change the value with (+) or (-).
Parameter N°1: Dt value
1.8 Difference between collector temperature (T1) and Tank
temperature (T2) to start the solar loading of the tank
(P1). (Default value 8°C, adjustable xx)
Parameter N°2: Maximum temperature in tank
2.90 Maximum desired water temperature in the Tank (T2).
(Default value 90°C, adjustable xx)
Main Pump (P1) function:
The pump is running:
- When the collector temperature (T1) is above the Tank
temperature (T2) + dt, adjustable on the parameter menu
(N°1=>default value 8°C)
- D
(Antilock braking function)
The pump is turned off:
- When the collector temperature (T1) decrease under the Tank
temperature (T2) + dt/2.
Example:
dt Setting
dt Setting / 2
P1
dt = T1 - T2