9
5.OF The overheat protection is deactivated (default value)
5.On The overheat protection is activated.
Parameter N°6: Setting level for overheat protection
6.14 Press the (+) or (-) key to choose the level to start the
overheat protection function. (Default value 140°C 14)
Adjustable 100°10 to 200°C20
Parameter N°7: Collector type
Use this parameter if your installation use vacuum tubes collector.
- This function could be used if the collector sensor is not directly
mounted on the collector. This function works in the following way.
Each 30 minutes the pump will be activated 30 seconds to measure
the correct value on the collector to avoid short charge cycle.
7.OF When Flat collector pannel is installed. (default value)
7.On When Tubes collector is installed.
Parameter N°8: Type of the extra function
8.OF The extra function is used to control an additional heat.
(default value)
T1
P2
P1
T3
T2
Extra Function to control
the pump coupled with
an external burner.