28VDC Operating Circuit (cont.)
PROBLEM
CAUSE
REMEDY
6. The 28VDC output voltage is
lower than expected.
C. The line drop compensation
setting within the GCM is set too
low.
C. Increase the setting. Contact
TLD, as this changes the GCM
calibration.
D. The GCM is limiting current.
D. Increase the limit if necessary.
This setting appears when the
28VDC circuit is in operation.
E. A faulty connection exists
between the output cable and the
aircraft.
E. Correct the connection.
F. The GCM is faulty.
F. Replace the GCM.