Page 5-18 Document Ref 947571-001 Rev 2
Installation Quantium 110 & 210 Installation Manual
Junction Box - Single Phase Suction (SPLIT POWER OPTION)
PE L1 L2 L3 N L N PE L N
* Note 1
Q200T 2-2 models
for all other models
TERMINALS IN CA170 BERNSTEIN
JUNCTION BOX
FORECOURT
WIRING
KIOSK
EQUIPMENT
* Note 1
Motor MCB
Calc MCB
2A
Lights MCB
1 PH MOTOR
(3x2.5mm²
cable or MICC)
CALC
(3x1.5mm² cable
or 2x1.0mm²
MICC)
LIGHTING
(3x1.5mm² cable or
2x1.0mm² MICC)
2A
940330 Rev 1
FORECOURT
WIRING
KIOSK
EQUIPMENT
* Note 1
Motor MCB
3 PH MOTOR
(4x1.5mm² cable
or MICC)
Lights MCB
Calc MCB
2A
2A
LIGHTING
(3x1.5mm² cable or
2x1.0mm² MICC)
CALC
(3x1.5mm² cable
or 2x1.0mm²
MICC)
940330 Rev 1
PE L1 L2 L3 N L N PE L N
* Note 1
10A motor circuit breaker
for models with 2 x EPZ :
Q200T 2-2 models
6A motor circuit breaker for
all other models
TERMINALS IN CA170 BERNSTEIN
JUNCTION BOX
Junction Box - Three Phase Suction (SPLIT POWER OPTION)