19
PBT 700
EN
Original manual
RECHARGE & RETEST
*Battery is discharged, the battery condition cannot be determined until it
is fully charged. Recharge & retest the battery.
RECHARGE & RETEST
VOL: xx.xx V
CCA: xxxx CCA/SAE
IR: xx.xxmΩ
BAD & REPLACE
*The battery will not hold a charge. It should be replaced immediately.
BAD & REPLACE
VOL: xx.xx V
CCA: xxxx CCA/SAE
IR: xx.xxmΩ
BAD CELL & REPLACE
*The battery has at least one cell short circuit. It should be replaced imme-
diately.
BAD CELL & REPLACE
VOL: xx.xx V
CCA: xxxx CCA/SAE
IR: xx.xxmΩ
LOAD ERROR
*The tested battery is bigger than 2000CCA/SAE or 200AH. Or the clamps
are not connected properly. Please fully charge the battery and retest after
excluding both previous reasons. If reading is the same, the battery should
be replaced immediately.
LOAD ERROR
SOC&SOHDisplay:PressdirectionalkeystoseeSOC&SOH:
GOOD & PASS
SOC: xx.xx V
■■■■■■■■■
□
90%
GOOD & PASS
SOC: xx.xx CCA/SAE
■■■■■■■■■
□
90%
15. Press the keytoselectresultprinting:YESorNO.Press«ENTER»to
conrmyourchoice.
IMPRIMER LES RÉ-
SULTATS ?
OUI / NON
16.Press«ENTER»returntoMAINMENUorremovethetestclampsfromthebatterypostsaftercomple-
tion of testing batteries to end test.