Topcon FH915/2400 Commands Reference Manual
12
modem/fh/brport
This command is used to specify the baud rate of the modem’s serial
port.
modem/fh/power
This command specifies the radio transmission power of the modem,
in watts. Currently there are two transmit power levels available: 250
mW and 1 W.
Structure
set,modem/fh/brport,N
, where N is a number between
1 and 4. Each number corresponds to a particular baud rate:
1 stands for 57600 baud, 2 stands for 38400, 3 stands for
19200, 4 stands for 9600
print,modem/fh/brport
Example
set,modem/fh/brport,1
- assigns the baud rate of the
modem’s serial port to 57600.
print,modem/fh/brport
- queries the current baud rate
Reply to
set %%OK -> brport=M
- positive acknowledgment, where M
is the current baud rate
Error in Command
- negative acknowledgment
Error in Argument
- negative acknowledgment
Reply to
print brport=M
, where M is the current baud rate
Error in Command
- negative acknowledgment
Structure
set,modem/fh/power,N
, where N is 0 or 1. Zero
stands for 1 W, unity stands for 250 mW.
print,modem/fh/power
Example
set,modem/fh/power,0
- assigns the transmit
power level to 1 W
print,modem/fh/power
Reply to
set %%OK -> power=M
- positive acknowledgment,
where M is the current power level
Error in Command
- negative acknowledgment
Error in Argument
- negative acknowledgment
Reply to
print power=M
- positive acknowledgment, where M is the
current power level
Error in Command
- negative acknowledgment