Topcon IS205 User Manual

Topcon IS205
170 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
IS
201
IS
203
IS
205
Rev.1
IS
SERIES
IMAGING STATION
INSTRUCTION MANUAL

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Topcon IS205 and is the answer not in the manual?

Topcon IS205 Specifications

General IconGeneral
BrandTopcon
ModelIS205
CategoryMeasuring Instruments
LanguageEnglish

Summary

Safety and Handling Precautions

General Handling Guidelines

Provides guidance on safe operation and handling of the instrument to prevent damage or injury.

Critical Safety Cautions

Lists critical warnings and cautions related to fire, electric shock, eye injury, and material damage.

Additional Safety Precautions

Details safety precautions regarding medical equipment, radio waves, and general handling.

Handling Cautions

Provides cautionary advice on electrical safety, laser beam exposure, and handling of the instrument.

Laser Safety Information

Laser Safety Standards and Precautions

Details laser safety standards, classification, and precautions for instrument operation.

Backlight and Key Light Adjustment

RAM Data Backup

Hardware Reset and Cover Sensor

Hardware Reset Procedure

Procedure for performing a hardware reset on the instrument when software reset fails.

Operating Panel and Power Management

Touch Panel and Power Control

Disabling touch panel for cleaning and proper instrument power-off procedure.

Auto Power Off Function

Remote Control System (RC-3)

PC Connectivity

Preparation for Measurement

Power Connection and Battery

Connecting power sources and understanding the battery power indicator.

Instrument Setup and Power On

Steps for setting up the instrument on a tripod and powering it on.

Tilt Correction (Angle)

Systematic Error Compensation

Connectivity Options

Prism Inclination and Measurement Error

Automatic Tracking and Collimation

Performing Automatic Tracking

Step-by-step guide to initiate and perform automatic tracking of a prism target.

Performing Automatic Collimation

Procedure for automatically searching and collimating a prism target.

Auto-Tracking Parameters

Standard Measurement Mode

Angle Measurement Procedures

Measuring horizontal and vertical angles, including HR/HL modes and angle holding.

Distance Measurement Modes

Covers measurement modes, prism constants, atmospheric correction, and non-prism ranges.

Continuous, Single/N-times, Fine/Coarse Measurement

Performing continuous, single/N-times, and fine/coarse distance measurements.

Stake Out (S.O) Operation

Performing stake out operations by inputting standard distances for HD, VD, or SD.

Coordinate Measurement Procedures

Setting occupied point coordinates, instrument/reflector height, and executing measurement.

Data Output

Program Mode Functions

Parameters Setting Mode

Check and Adjustment

Instrument Constant Check and Adjustment

Procedure to check and adjust the instrument constant using a baseline measurement.

Optical Axis Checks

Checking alignment of EDM/Theodolite, Laser Pointer, and Auto-Tracking optic axes.

Systematic Error Compensation

Adjusting compensation for systematic errors like axis offsets and collimation.

Prism/Non-Prism Constant Correction

Atmospheric Correction

Atmospheric Correction Calculation

Presents formulas for calculating atmospheric correction based on temperature and pressure.

Setting Atmospheric Correction Values

Directly inputting measured temperature, pressure, or PPM for atmospheric correction.

Refraction and Earth Curvature Correction

Power Source and Charging

Onboard Battery BT-65Q Usage

Instructions for removing, charging, and installing the BT-65Q battery.

Precautions for Use

Message and Error Displays

Specifications

Related product manuals