Topcon GPT-3002W Series User Manual

Topcon GPT-3002W Series
188 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
GPT-3000W
SERIES
GPT-3002W
GPT-3003W
GPT-3005W
GPT-3007W
PULSE TOTAL STATION
INSTRUCTION MANUAL

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Topcon GPT-3002W Series and is the answer not in the manual?

Topcon GPT-3002W Series Specifications

General IconGeneral
ModelGPT-3002W Series
CategoryMeasuring Instruments
TypeTotal Station
Accuracy2"
Range with prism3, 000 m
Telescope Magnification30x
Working Temperature Range-20°C to +50°C
Wireless CommunicationBluetooth
Distance Measurement Range3, 000 m
Distance Measurement Accuracy±(2mm + 2ppm)
CompensatorDual-axis

Summary

FOREWORD

General Handling Precautions

Provides essential guidelines for safe and proper handling of the instrument.

Display for Safe Use

Explains important warning displays and icons for user safety.

Safety Cautions

Lists critical safety precautions to prevent hazards during instrument operation.

Laser Safety

Details safety measures and classifications for laser beams used by the instrument.

NOMENCLATURE AND FUNCTIONS

Operating Key

Details the functions of the instrument's keys, including power and soft keys.

Function Key (Soft Key)

Explains the context-sensitive functions assigned to soft keys (F1-F4).

Star key mode

Describes how to access and use instrument options via the star key.

PREPARATION FOR MEASUREMENT

Setting Instrument Up For Measurement

Step-by-step guide on leveling and centering the instrument on a tripod.

Power Switch Key ON

Procedure for turning on the instrument after leveling.

Battery Power Remaining Display

Explains how to interpret the battery power indicator and its implications.

Vertical and Horizontal Angle Tilt Correction

Describes the tilt sensor functionality for angle correction.

ANGLE MEASUREMENT

Measuring Horizontal Angle Right and Vertical Angle

Procedure for measuring horizontal and vertical angles to a target.

Measuring from the Required Horizontal Angle

Covers setting and measuring angles using specific horizontal angle values.

Repetition Angle Measurement

Details the process for performing repeated angle measurements for accuracy.

DISTANCE MEASUREMENT

Setting of the Atmospheric Correction

Instructions for setting atmospheric correction values based on temperature and pressure.

Offset Measurement

Covers various offset measurement modes like angle, distance, plane, and column.

COORDINATE MEASUREMENT

Setting Coordinate Values of Occupied Point

How to input the instrument's occupied point coordinates.

SPECIAL MODE (Menu Mode)

DATA COLLECTION

Accesses the data collection functions and menus.

LAYOUT

Enables layout operations, setting points, and using coordinate data.

MEMORY MANAGER MODE

Provides access to internal memory management functions.

Remote Elevation measurement (REM)

Procedure for measuring the elevation of a target without direct prism setup.

Missing Line Measurement (MLM)

Calculates distances and bearings between two prisms automatically.

Setting Mode 1

Configures settings like minimum reading and auto power off.

Auto Power Off

Manages automatic power-off settings to conserve battery.

Vertical and Horizontal Angle Tilt Correction ( Tilt ON/OFF)

Enables or disables tilt correction for vertical and horizontal angles.

Systematic Error of Instrument Correction

Applies corrections for systematic errors in instrument measurements.

DATA COLLECTION

Operational Procedure of DATA COLLECT

Detailed steps for performing data collection operations.

Data Collect Offset Measurement mode

Using offset measurement modes within data collection.

LAYOUT

Executing a Layout

Step-by-step instructions for performing layout operations.

MEMORY MANAGER MODE

Searching Data

Methods for searching recorded data files.

FILE MAINTENANCE

Operations for renaming, searching, and deleting files.

Data Communications

Managing data transfer between the instrument and a computer.

Initialization

Resets the instrument's internal memory to its default state.

SET AUDIO MODE

SETTING THE PRISM / NON-PRISM CONSTANT VALUE

SETTING ATMOSPHERIC CORRECTION

CORRECTION FOR REFRACTION AND EARTH CURVATURE

POWER SOURCE AND CHARGING

On-board Battery BT-52QA

Information on removing, charging, and refreshing the on-board battery.

SELECTING MODE

CHECK AND ADJUSTMENT

Checking and adjusting of instrument constant

Procedure for verifying and setting instrument constants.

Checking the Optical Axis

Checks the alignment of the optical axes for EDM and theodolite.

Checking the optical axis of EDM and theodolite

Detailed steps to verify EDM and theodolite optical axis alignment.

Checking the optical axis of Laser pointer

Ensures the laser pointer's optical axis is aligned with the telescope.

Checking/Adjusting the Theodolite Functions

General guidance on checking and adjusting theodolite functions.

Adjustment of Compensation Systematic Error of Instrument

Corrects systematic errors related to instrument collimation and axis alignment.