GPT-3000W
SERIES
GPT-3002W
GPT-3003W
GPT-3005W
GPT-3007W
PULSE TOTAL STATION
INSTRUCTION MANUAL

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Topcon GPT-3000W Series and is the answer not in the manual?

Topcon GPT-3000W Series Specifications

General IconGeneral
BrandTopcon
ModelGPT-3000W Series
CategoryMeasuring Instruments
LanguageEnglish

Summary

Topcon GPT-3000W Instruction Manual

General Handling Precautions

Essential guidelines for safe and correct operation and handling of the instrument.

Safety Cautions

Important warnings and precautions to prevent danger and damage during use.

Nomenclature and Functions

Preparation for Measurement

Setting Up the Instrument

Steps for mounting, leveling, and centering the instrument on a tripod.

Tilt Correction Settings

Configuring vertical and horizontal angle tilt correction for accuracy.

Angle Measurement

Measuring Horizontal and Vertical Angles

Procedure for measuring horizontal and vertical angles to a target.

Distance Measurement

Atmospheric Correction Settings

Setting atmospheric correction values for accurate distance measurements.

Prism and Non-Prism Constant Settings

Setting correction values for prism and non-prism targets.

Continuous Distance Measurement

Performing distance measurements continuously.

Coordinate Measurement

Setting Occupied Point Coordinates

Defining the instrument's position and coordinate system origin.

Setting Instrument Height

Inputting the height of the instrument for calculations.

Setting Target (Prism) Height

Inputting the height of the prism or target for measurements.

Executing Coordinate Measurement

Procedure for performing coordinate measurements after setup.

Special Mode (Menu Mode)

Application Measurements (Programs)

Accessing various measurement applications like REM, MLM, Area Calculation.

Data Collection

Data Collection Operational Procedures

Step-by-step guide for collecting data, including searching and inputting.

Layout Operations

Layout Preparation

Setting the GRID FACTOR, selecting coordinate files, and setting points.

Executing a Layout

Procedure for laying out points based on stored data.

Setting New Points

Methods for defining new points, including Side Shot and Resection.

Memory Manager Mode

File Maintenance

Operations for managing files: renaming, searching, and deleting.

Data Communications

Sending and loading data files via computer connection.

Setting Prism and Non-Prism Constant Value

Setting Atmospheric Correction

Setting Atmospheric Correction Value

Procedure for inputting temperature and pressure for correction.

Power Source and Charging

On-board Battery BT-52QA

Information on removing, charging, and refreshing the on-board battery.

Check and Adjustment

Instrument Constant Check

Procedures for checking and adjusting instrument constants for prism/non-prism modes.

Checking the Optical Axis

Verifying alignment of EDM, theodolite, laser pointer, and optical plummet.

Theodolite Function Checks

Checking and adjusting plate level, circular level, and cross-hair alignment.

Instrument Collimation

Procedure to ensure the telescope's line of sight is perpendicular to the instrument's axis.

Setting Instrument Constant Value

How to input or change the instrument constant values.

Systematic Error Adjustment

Adjusting for systematic errors in collimation and axes.

Precautions

Battery System

Error Displays