Guidelines for safe and proper handling of the instrument to ensure optimal performance and longevity.
Important safety warnings regarding potential risks such as fire, electric shock, and eye injury.
Information on laser safety classification and precautions for safe use of laser pointers and plum lasers.
Identification and description of the main parts and components of the GPT-3000W series instrument.
Step-by-step guide on mounting, leveling, and centering the instrument on a tripod for precise measurements.
Explanation of automatic tilt correction for vertical and horizontal angles to ensure precise measurements.
Procedure for measuring horizontal and vertical angles by collimating targets.
Procedure for setting atmospheric correction values based on measured temperature and pressure.
Instructions for setting prism and non-prism constant correction values for accurate distance measurements.
Steps for performing continuous distance measurements and displaying angle and distance data.
Procedure for setting the instrument's occupied point coordinates to establish a reference origin.
Steps to measure unknown point coordinates by entering instrument and prism heights.
Enabling or disabling tilt correction for vertical and horizontal angles for improved accuracy.
Detailed steps for executing the data collection process, including entering points and measurements.
Detailed procedure for executing layout tasks, including point recall and distance/angle guidance.
Procedures for sending and loading data files and setting communication parameters.
Instructions for setting prism constant correction values for non-Topcon prisms for accurate measurements.
Procedure for setting atmospheric correction values directly using measured temperature and pressure.
Formulas for calculating horizontal and vertical distances considering refraction and earth curvature.
Information on removing, charging, and refreshing the on-board BT-52QA battery.
Step-by-step guide on how to configure various instrument settings through the selecting mode.
Procedures for checking and adjusting instrument constants for prism and non-prism modes.
Methods for checking the alignment of the optical axis for EDM, theodolite, and laser pointer.
Detailed steps to verify the matching of optical axes for EDM and theodolite components.
Procedure to check and adjust the laser pointer's optical axis to coincide with the telescope's axis.
A table listing common error codes, their descriptions, and recommended countermeasures.
Details on the measurement accuracy for non-prism and prism modes under various conditions.