EasyManua.ls Logo

Topcon GTS-235 User Manual

Topcon GTS-235
163 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
ELECTRONIC TOTAL STATION
GTS-230
SERIES
GTS-233
GTS-235
GTS-236
INSTRUCTION MANUAL
GTS-239

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Topcon GTS-235 and is the answer not in the manual?

Topcon GTS-235 Specifications

General IconGeneral
BrandTopcon
ModelGTS-235
CategoryMeasuring Instruments
LanguageEnglish

Summary

FOREWORD

2 PREPARATION FOR MEASUREMENT

2.2 Setting Instrument Up For Measurement

Covers the precise procedure for setting up the instrument on a tripod and leveling.

3 ANGLE MEASUREMENT

3.1 Measuring Horizontal Angle Right and Vertical Angle

Details the procedure for measuring horizontal and vertical angles with targets.

4 DISTANCE MEASUREMENT

4.3 Distance Measurement (Continuous Measurement)

Describes how to perform continuous distance measurements to a target.

5 COORDINATE MEASUREMENT

5.1 Setting Coordinate Values of Occupied Point

Details how to input the instrument's occupied point coordinates for reference.

5.2 Setting Height of the Instrument

Explains how to input the height of the instrument for coordinate calculations.

5.3 Setting Height of Target (Prism Height)

Guides on inputting the prism height for accurate Z coordinate measurements.

5.4 Execution of Coordinate Measuring

Describes the process of measuring coordinates of unknown points.

6 SPECIAL MODE (Menu Mode)

6.1 Application Measurement (PROGRAMS)

Covers special measurement applications like REM, MLM, Z Coordinate, Area, and Point to Line.

7 DATA COLLECTION

7.2 Operational Procedure of “DATA COLLECT”

Details the step-by-step process for collecting measurement data.

7.3 Data Collect Offset Measurement mode

Explains offset measurement methods for collecting data in difficult-to-access locations.

7.6 Setting Parameter of Data Collect [CONFIG.]

Allows configuration of various data collection parameters like distance mode and data confirmation.

8 LAYOUT

8.2 Executing a Layout

Details the procedures for executing layout tasks using stored points.

8.3 Setting a New Point

Explains methods for establishing new points, such as side shot and resection.

9 MEMORY MANAGER MODE

9.2 Searching Data

Describes methods for searching recorded data files like MEAS. DATA and COORD. DATA.

9.7 Data Communications

Covers sending data to a computer and loading data from it.

11 SETTING THE PRISM CONSTANT VALUE

11.1 Setting the Prism Constant Value

Allows setting the prism constant correction value for accurate distance measurements.

12 SETTING ATMOSPHERIC CORRECTION

12.2 Setting of Atmospheric Correction Value

Guides on inputting temperature and pressure to automatically calculate correction values.

17 CHECK AND ADJUSTMENT

17.1 Checking and adjusting of instrument constant

Describes procedures to check and adjust the instrument's internal constant.

17.3 Checking/Adjusting the Theodolite Functions

Covers adjustments for plate level, circular level, vertical cross-hair, collimation, and optical plummet.

17.5 Adjustment of Compensation Systematic Error of Instrument

Explains the procedure for adjusting systematic errors in the instrument's axes.

18 PRECAUTIONS

General Precautions

Lists essential precautions for instrument handling, storage, cleaning, and maintenance.

20 BATTERY SYSTEM

22 ERROR DISPLAYS

Error Displays

Lists common error codes, their descriptions, and recommended countermeasures.

Related product manuals