EasyManua.ls Logo

Topcon GPT-3000W Series - Entering PCODE; ID from the List of PCODE

Topcon GPT-3000W Series
188 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7-9
7 DATA COLLECTION
7.2.3 Entering PCODE / ID from the list of PCODE
You can also enter PCODE / ID from the list of PCODE.
Operating procedure Operation Display
1
Move the arrow to the PCODE or ID in the DATA
COLLECT mode, press the [F2](SRCH) key.
[F2]
2
By pressing the following keys, the register
number will increase or decrease.
[ ]or[ ]:Increasing or Decreasing one by one
[ ]or[ ]:By ten Increasing or Decreasing. *1)
[]or[]
[]or[]
3
Press the [F4](ENTER) key.
[F4]
*1) To edit the PCODE library, press the [F1](EDIT) key.
To delete the PCODE registered with shown an arrow, press the [F3](CLR) key.
PCODE can be edited in DATA COLLECT menu 2/2 or MEMORY MANAGER menu 2/3.
PT# :PT-02
PCODE
R.HT : 1.200 m
INPUT SRCH MEAS ALL
001:PCODE01
002:PCODE02
EDIT ––– CLR ENTER
031:PCODE31
032:TOPCON
033:HILTOP
EDIT ––– CLR ENTER
PT# :PT-02
PCODE :TOPCON
R.HT
1.200 m
INPUT SRCH MEAS ALL

Table of Contents