EasyManua.ls Logo

Topcon GPT-3007 User Manual

Topcon GPT-3007
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
GPT-3000
SERIES
GPT-3002
GPT-3003
GPT-3005
GPT-3007
PULSE TOTAL STATION
INSTRUCTION MANUAL

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Topcon GPT-3007 and is the answer not in the manual?

Topcon GPT-3007 Specifications

General IconGeneral
BrandTopcon
ModelGPT-3007
CategoryMeasuring Instruments
LanguageEnglish

Summary

General Handling Precautions

Display for Safe Use

Safety Cautions

Laser Safety

1 NOMENCLATURE AND FUNCTIONS

1.1 Nomenclature

Identifies and labels the physical components of the instrument.

2 PREPARATION FOR MEASUREMENT

2.2 Setting Instrument Up For Measurement

Explains the process of leveling and centering the instrument on a tripod.

2.5 Vertical and Horizontal Angle Tilt Correction

Explains the tilt correction feature for accurate angle measurements.

3 ANGLE MEASUREMENT

3.1 Measuring Horizontal Angle Right and Vertical Angle

Explains the basic process of measuring angles to a target.

4 DISTANCE MEASUREMENT

4.1 Setting of the Atmospheric Correction

Inputting atmospheric values to correct distance measurements.

4.2 Setting of the Correction for Prism Constant / Non-prism Constant

Setting prism/non-prism constants for accurate distance measurements.

5 COORDINATE MEASUREMENT

5.1 Setting Coordinate Values of Occupied Point

Procedure to set the instrument's occupied point coordinates.

5.4 Execution of Coordinate Measuring

Steps for performing coordinate measurements after setup.

6 SPECIAL MODE (Menu Mode)

6.1 Application Measurement (PROGRAMS)

Accesses specialized measurement programs like REM, MLM, etc.

7 DATA COLLECTION

7.2 Operational Procedure of DATA COLLECT

Step-by-step guide for performing data collection.

7.7 Setting Parameter of Data Collect [CONFIG.]

Configuring various parameters for data collection operations.

8 LAYOUT

8.2 Executing a Layout

Step-by-step guide for performing layout tasks.

8.3 Setting a New Point

Procedures for establishing new points.

9 MEMORY MANAGER MODE

9.7 Data Communications

Managing data transfer between the instrument and a computer.

11 SETTING THE PRISM / NON-PRISM CONSTANT VALUE

12 SETTING ATMOSPHERIC CORRECTION

12.2 Setting of Atmospheric Correction Value

How to input temperature and pressure values for correction.

13 CORRECTION FOR REFRACTION AND EARTH CURVATURE

14 POWER SOURCE AND CHARGING

14.1 On-board Battery BT-52QA

Details on using and charging the on-board battery.

16 SELECTING MODE

16.1 Items of the Selecting Mode

Overview of all available modes and their selectable items.

16.2 How to Set Selecting Mode

Step-by-step guide to configuring various instrument modes.

17 CHECK AND ADJUSTMENT

17.1 Checking and adjusting of instrument constant

Verifying and setting instrument constants for accuracy.

17.2 Checking the Optical Axis

Procedures to check and align the optical axes of EDM and telescope.

18 PRECAUTIONS

Related product manuals