EasyManua.ls Logo

Topcon GPT-3002W Series - MEMORY MANAGER MODE

Topcon GPT-3002W Series
188 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9-1
9 MEMORY MANAGER MODE
9 MEMORY MANAGER MODE
The following items for internal memory are available in this mode.
1) FILE STATUS : Checking the number of stored data / Remaining internal memory
capacity.
2) SEARCH : Searching the recorded data.
3) FILE MAINTAN. : Deleting files / Editing file name
4) COORD. INPUT : Inputting coordinate data into Coord. data file.
5) DELETE COORD. : Deleting coordinate data from Coord. data file.
6) PCODE INPUT : Inputting PCODE DATA into PCODE Library
7) DATA TRANSFER : Sending measured data or coordinate data or PCODE Library data /
Uploading coordinate data or PCODE Library data / Setting
communication parameters
8) INITIALIZE : Initializing internal memory.
Memory manager menu operation
By pressing the [MENU] key, the instrument will be in MENU 1/3 mode.
Press the [F3](MEMORY MGR. ) key, the menu of MEMORY MGR. 1/3 will be shown.
Normal measurement mode
MENU 1/3
F1:DATA COLLECT
F2:LAYOUT
F3:MEMORY MGR. P
MEMORY MGR. 1/3
F1:FILE STATUS
F2:SEARCH
F3:FILE MAINTAN.P
[ESC]
[MENU]
MEMORY MGR. 2/3
F1:COORD. INPUT
F2:DELETE COORD
F3:PCODE INPUT P
MEMORY MGR. 3/3
F1:DATA TRANSFER
F2:INITIALIZE
P
[F3]
[F4]
[F4]
[F4]
MEMORY MGR. MENU 1/3
MEMORY MGR. MENU 2/3
MEMORY MGR. MENU 3/3

Table of Contents