22 (64)
MAINTENANCE OPERATIONS
TKU--- C 01140--- 1 EN 0404
D
DD
D Check Hand Portable Fire Extinguisher
Gauge pointer in green area.
No corrosion.
Firmly mounted.
Visually check that seals are in place.
D
DD
D Check lights
Front
Rear
Optional lights
D
DD
D Check gauges and indicator lights
DDEC signal lights must go off about 5 sec
after the power has been switched on.
Engine temperature should be below 99_C.
Engine oil pressure: at least 0.35
bar when idling, at least 1.9 bar when at 1800 rpm.
Brake system oil pressure ; warning light
illuminates when pressure drops too low.
Alternator charging voltage; approx. 26--28 V.
Transmission oil pressure; should be
16.5 – 21.4 bar.
D
DD
D Fill fuel tank
Shut off engine before filling.
Insure machine is suitably grounded.
Do not overfill.
Do not fill fuel tank to the top. F uel expands
when it becomes warm and can overflow.
If using quick fill, e nsure that the system
supplier’s instructions are followed.
Maintenance