HydraulicSystem
Maintenance
ChangingtheHydraulicFluid
ServiceInterval:Every800hours
Changethehydraulicuidafterevery800operating
hours,innormalconditions.Iftheuidbecomes
contaminated,contactyourlocalTorodistributor
becausethesystemmustbeushed.Contaminateduid
looksmilkyorblackwhencomparedtocleanoil.
1.Turntheengineoffandraisethehood.
2.Disconnectthecasereturnlinefromthebottomof
thereservoirandletthehydraulicuidowintoa
largedrainpan.Connectthelinewhenthehydraulic
uidstopsdraining.
3.Fillthereservoirwithapproximately7.5gallons
(28.4l)ofhydraulicuid;refertoCheckingthe
HydraulicFluid.
Important:Useonlythehydraulicuids
specied.Otheruidscouldcausesystem
damage.
4.Installthereservoircap.Starttheengineanduseall
ofthehydrauliccontrolstodistributehydraulicuid
throughoutthesystem.Alsocheckforleaks;then
stoptheengine.
5.Checktheuidlevelandaddenoughtoraisethelevel
totheFULLmarkonthedipstick.Donotoverll.
ReplacingtheHydraulicFilters
ServiceInterval:Aftertherst200hours
Every800hours
Changethe2hydraulicltersinitiallyaftertherst200
operatinghours.Thereafter,changetheltersafter
every800operatinghours,innormalconditions.
UseTororeplacementltersPartNo.94-2621forthe
rear(cuttingunit)ofthemachineand75-1310forthe
front(charge)ofthemachine.
Important:Useofanyotherltermayvoidthe
warrantyonsomecomponents.
1.Positionthemachineonalevelsurface,lowerthe
cuttingunits,stoptheengine,engagetheparking
brakes,andremovetheignitionkey.
2.Cleantheareaaroundtheltermountingarea.Place
adrainpanunderthelterandremovethelter
(
Figure81andFigure82).
3.Lubricatethenewltergasketandllthelterwith
hydraulicuid.
Figure81
1.Hydrauliclter
Figure82
1.Hydrauliclter
4.Ensurethattheltermountingareaisclean.Screw
thelteronuntilthegasketcontactsthemounting
plate;thentightenthelteranadditional1/2turn.
5.Starttheengineandletitrunforabouttwominutes
topurgeairfromthesystem.Stoptheengineand
checkforleaks.