Loading...
FuelSystem
Maintenance
DANGER
Undercertainconditions,dieselfuelandfuel
vaporsarehighlyammableandexplosive.A
reorexplosionfromfuelcanburnyouand
othersandcancausepropertydamage.
Useafunnelandllthefueltankoutdoors,
inanopenarea,whentheengineisoffand
iscold.Wipeupanyfuelthatspills.
Donotllthefueltankcompletelyfull.Add
fueltothefueltankuntilthelevelistothe
bottomofthellerneck.
Neversmokewhenhandlingfuel,andstay
awayfromanopenameorwherefuel
fumesmaybeignitedbyaspark.
Storefuelinaclean,safety-approved
containerandkeepthecapinplace.
ServicingtheWater
Separator
ServiceInterval:Beforeeachuseordaily—Drain
waterorothercontaminantsfrom
thefuellter/waterseparator.
Every400hours—Replacethefuel-lter
canister.
ServicethewaterseparatorasshowninFigure37.
Afterreplacingthewaterseparator,turnthekeytoON
for10seconds,butdonotstarttheengine.Turnthe
keyoffandrepeatthis2moretimes.
g031412
Figure37
DrainingtheFuelTank
ServiceInterval:Every800hours—Drainandclean
thefueltank.
Beforestorage—Drainandcleanthefueltank.
Inadditiontothelistedserviceinterval,drainandclean
thetankifthefuelsystembecomescontaminatedorif
youarestoringthemachineforanextendedperiod.
Usecleanfueltoushoutthetank.
InspectingtheFuelLines
andConnections
ServiceInterval:Every400hours/Yearly(whichever
comesrst)
Inspectthefuellinesfordeterioration,damage,or
looseconnections.
41

Table of Contents