Installing the Battery
1. Position the battery in the tray with the terminal
posts opposite from the hydraulic tank ( Figure
57 ).
2. Install the positive (red) battery cable to the
positive (+) battery terminal.
3. Install the negative (black) battery cable and
ground wire to the negative (-) battery terminal.
Note: For MyRide machines, ensure that the
ground cable does not rub against the trailing
arm or lower shock mount ( Figure 60 ).
g334253
Figure 59
1. Ensure that the ground
cable does not rub against
the lower shock mount.
3. Ground cable
2. Ensure that the ground
cable does not rub against
the trailing arm.
4. Secure the cables with 2 bolts, 2 washers, and
2 locknuts ( Figure 57 ).
5. Slide the red terminal boot onto the positive (+)
battery terminal.
6. Secure the battery with the rubber strap ( Figure
57 ).
Servicing the Fuses
The electrical system is protected by fuses. It requires
no maintenance; however , if a fuse blows check the
component and circuit for a malfunction or short.
The fuses are located on the right console next to the
seat ( Figure 60 ).
1. T o replace the fuses, pull out the fuse to remove
it.
2. Install a new fuse ( Figure 60 ).
g036858
Figure 60
1. Fuse cover
3. Fuel-shutof f valve
2. Fuse holder
50