Troubleshooting
37
PROBLEM
CORRECTIVE ACTION
POSSIBLE CAUSES
T
raction unit does not drive.
1.
Flow divider valve lever is in
9 o’clock position.
1.
Move lever to the 12 to 10
o’clock position.
2.
Hydro fluid level low
.
3. T
raction pump drive coupler
is loose or broken.
4.
Pump and/or wheel motor is
defective or damaged.
5.
Control valve is defective or
damaged.
6.
Relief valve is defective or
damaged.
2.
Add hydro fluid to reservoir
.
3.
Contact Service Dealer
.
4.
Contact Service Dealer
.
5.
Contact Service Dealer
.
6.
Contact Service Dealer
.
When at rest, loader arms creep
downward more than 3” per hour
(less than 3” an hour is normal for
this traction unit).*
1. V
alve spool leakage
1.
Contact Service Dealer
.
When at rest, loader arms settle
downward 2” quickly and then
stop.*
1.
Cylinder seals are leaking
2.
Cylinder rephase valve is
leaking
1.
Replace seals.
2.
Contact Service Dealer
.
* Tested with warm oil and no more than 515 lbs in the bucket. Measure the downward drop at the attachment