Problem Corrective ActionPossible Causes
The engine dies when the water
system is engaged.
1. The throttle is in the wrong
operating position.
1. Put the throttle in the FAST
position when aerating.
ygg
2. The engine speed is set
incorrectly.
2. Adjust the carburetor fast
setting to 3450–3550 RPM.
3. Engine power is low. 3. Fuel is contaminated, there is a
plugged fuel filter or air filter, or
there is a bad spark plug.
4. Have the system serviced by
an Authorized Toro Distributor.
The engine does not start (will not
engage the starter).
1. The traction bail is not in the
neutral position.
1. Correct the traction bail
position.
gg )
2. The neutral switch tab is out of
adjustment.
2. Adjust the switch tab until the
red traction light is OFF in
neutral.
3. The battery voltage is low. 3. Check the battery.
4. There is a malfunction is the
electrical system.
4. Check the circuit breaker and
electrical connections.
The unit is not producing aeration
holes (the pump or water valve will
not start).
1. The supply hose is kinked,
there is a restriction in the line,
or the valve at the water source
is only partially opened.
1. Correct the condition.
2. There is inadequate water
pressure or flow from the
source.
2. Check the water pressure (from
the water source) at the inlet
(8 gpm – 40 psi).
3. Check the water pressure at
the gauge when the pump is
engaged if the water pressure
drops to less than 25 psi, but
was initially higher.
3. Replace the water filter.
The unit stops aerating in one
direction or stops aerating in the
lowest hole spacing.
1. The supply hose is kinked,
there is a restriction in the line,
or the valve at the water source
is only partially opened.
1. Correct the condition.
2. There is inadequate water
pressure or flow from the
source.
2. Check the water pressure (from
the water source) at the inlet
(8 gpm – 40 psi).
3. Check the water pressure at
the gauge when the pump is
engaged if the water pressure
drops to less than 25 psi, but
was initially higher.
3. Replace the water filter.
4. The neutral switch tab is out of
adjustment
4. Adjust the switch tab until the
red traction light is ON while
the traction bail is actuated in
both directions.
5. The red traction light must be
OFF, when in neutral, to allow
the engine start interlock to
function.

Table of Contents

Other manuals for Toro Hydroject 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toro Hydroject 3000 and is the answer not in the manual?

Toro Hydroject 3000 Specifications

General IconGeneral
BrandToro
ModelHydroject 3000
CategoryTiller
LanguageEnglish

Related product manuals