RemovingtheBlades
Replacethebladeswhenthemachinehitsasolid
objectorwhenabladeisoutofbalanceorbent.Use
onlygenuineTororeplacementblades.
1.Useablockofwoodtoholdeachbladesteady
andturnthebladeboltcounterclockwiseas
showninFigure40.
g232790
Figure40
2.RemoveeachbladeasshowninFigure41.
g016530
Figure41
1.Spindle(2)3.Blade(2)
2.Bladedriver(2)4.Bladebolt(2)
3.Inspectthepinsonthebladedriversforwear
anddamage.
InstallingtheBlades
1.Installtherstbladesothatitishorizontal,along
withallmountinghardwareasshowninFigure
41.
Note:Tightentheboltwithyourngers.
Important:Positionthecurvedendsofthe
bladestopointtowardthemachinehousing.
Besuretonesttheraisedareasoneach
bladedriverwiththerecessesintheheadof
itscorrespondingspindle,andthepinson
theothersideofeachbladedriverwiththe
holesinitscorrespondingblade.
2.Steadyeachbladewithaboardandturnthe
bladeboltclockwisewithatorquewrenchas
showninFigure42;torquethebladeboltto82
N∙m(60ft-lb).
g232801
Figure42
3.Rotatetheinstalledblade1/4turnuntilitis
vertical,andinstalltheotherbladeinthesame
mannerastherst(refertostep1).
Note:Thebladesshouldbeperpendicular,
forminganinverted“T”asshowninFigure43.