(Refer to Initialization of Memory Data of QA02 and setting data of signal board.)
Adjusting the Data
Pressing of VOLUME +/- button will change the value of data in the range from 00H to FFH.
The variable range depends on the adjusting item.
I2C Bus Off
Turn off I2C communication between IC700 and IC400.
1) Press and hold the CALL button on the remote control, then press the Volume + button on
the TV.
2) Display "BUS Off" OSD.
3) I2C communication turned off.
Note:
To return Bus on status, press and hold the CALL button on the remote control, then press the
Volume + button on the TV again. TV will be turned off and automatically turned on, then
status will be Bus On.
Setting TVOP
Enter to service mode and select menu of TVOP by pressing P or P during display of
adjustment menu. After selecting TVOP, press + or - to set I2C check function to disable or
enable as below.
Setting Panel Option Data
TVOP FUNCTION DESCRIPTION 1 0 (Normal)
D5 (bit5) I2C check between IC700 and IC400. (WDT) Disable Enable