5) Initialization progress dialog including model name and panel vendor is shown.
Progress status is "WRITING".
6) Progress status is changed "OK" and power cycle (automatically). Then QA02 initialization has
been completed.
7) Enter the service mode and select version check mode. Confirm if model name and model id set
is correct. If not, repeat steps 1) to 6).
Note:
In case initialization by setting wrong MODEL ID is done, there is a possibility of abnormal
display.
8) Set I2C check function of TVOP to enable.
9) Check the picture carefully. If necessary, adjust any adjustment item above.
Perform "Auto tune" on the owner's manual.
MODEL ID (HEX) Model name Panel vendor
0x01
32XV505D/503D/504D
SAM
0x02 IPS
0x03
37XV505D/503D/504D
LPL
0x04 IPS
0x05 42XV505D/503D/504D CMO
0x06
32XV500P/501P
SAM
0x07 IPS
0x08
37XV500P/501P
LPL
0x09 IPS
0x10 42XV500P/501P CMO
0x11 42XV505D/503D/504D LPL
0x12 42XV500P/501P LPL